Effect of CBCT-based root visualization on virtual bracket placement in a CAD/CAM indirect bonding workflow

The adoption of indirect bonding in orthodontics has grown substantially in recent years. The incorporation of a computer-aided design/computer-aided manufacturing (CAD/CAM) approach can improve bracket positioning precision and potentially reduce treatment time. Additionally, cone-beam computed tomography (CBCT) enables three-dimensional evaluation of both crowns and roots, and the integration of digital models with CBCT data may enhance the precision of the indirect bonding process. This study aims to evaluate the precision of bracket placement in indirect bonding, with and without the superimposition of CBCT images onto digital models, as performed by orthodontists. A total of 22 orthodontists participated in this study. Each orthodontist performed virtual bonding on digital models using OrthoAnalyzer™ software (3Shape A/S, Copenhagen, Denmark) in two stages: first, visualizing only the clinical crowns, and after a minimum interval of 15 days, visualizing both the crowns and roots with the aid of CBCT images. Bracket positioning discrepancies between the two bonding sessions were measured to assess intra-operator consistency. Positional deviations were analyzed in three dimensions: vertical, horizontal, and angular. Statistical analysis was conducted at a significance level of 5%. Positional deviations were within clinically acceptable limits for both horizontal and vertical dimensions, with deviations measuring less than 0.5 mm. However, angular deviations exceeded the clinically acceptable threshold of 2° for certain dental elements. The results indicate that orthodontists maintained consistent precision in the vertical and horizontal dimensions. However, the integration of CBCT data affected the precision of angular measurements. These findings suggest that incorporating CBCT into the indirect bonding workflow alters bracket placement in certain angular dimensions for specific teeth, which is critical for achieving optimal orthodontic outcomes.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-02-19
DOI
https://doi.org/10.1186/s12903-026-07907-5
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of CBCT-based root visualization on virtual bracket placement in a CAD/CAM indirect bonding workflow

Gribel Bf, Ivanise Cardoso da Silva, Deise Caldas Kühlman, José Augusto Mendes
BMC Oral Health
Orthodontics and Dentofacial Orthopedics
article

Effect of CBCT-based root visualization on virtual bracket placement in a CAD/CAM indirect bonding workflow

Gribel Bf, Ivanise Cardoso da Silva, Deise Caldas Kühlman, José Augusto Mendes
article en

Abstract

The adoption of indirect bonding in orthodontics has grown substantially in recent years. The incorporation of a computer-aided design/computer-aided manufacturing (CAD/CAM) approach can improve bracket positioning precision and potentially reduce treatment time. Additionally, cone-beam computed tomography (CBCT) enables three-dimensional evaluation of both crowns and roots, and the integration of digital models with CBCT data may enhance the precision of the indirect bonding process. This study aims to evaluate the precision of bracket placement in indirect bonding, with and without the superimposition of CBCT images onto digital models, as performed by orthodontists. A total of 22 orthodontists participated in this study. Each orthodontist performed virtual bonding on digital models using OrthoAnalyzer™ software (3Shape A/S, Copenhagen, Denmark) in two stages: first, visualizing only the clinical crowns, and after a minimum interval of 15 days, visualizing both the crowns and roots with the aid of CBCT images. Bracket positioning discrepancies between the two bonding sessions were measured to assess intra-operator consistency. Positional deviations were analyzed in three dimensions: vertical, horizontal, and angular. Statistical analysis was conducted at a significance level of 5%. Positional deviations were within clinically acceptable limits for both horizontal and vertical dimensions, with deviations measuring less than 0.5 mm. However, angular deviations exceeded the clinically acceptable threshold of 2° for certain dental elements. The results indicate that orthodontists maintained consistent precision in the vertical and horizontal dimensions. However, the integration of CBCT data affected the precision of angular measurements. These findings suggest that incorporating CBCT into the indirect bonding workflow alters bracket placement in certain angular dimensions for specific teeth, which is critical for achieving optimal orthodontic outcomes.

BMC Oral HealthVol. 26(1)
Universidade do Estado do Rio de Janeiro (BR), Faculdade de Ciências Médicas de Minas Gerais (BR)
Openalex Percentile: Top 50%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.