Single-ended protection method based on spectrum of natural frequency for lines in MMC-HVDC grids

This paper proposes an improved single-ended protection method for Modular Multilevel Converter-based High Voltage Direct Current (MMC-HVDC) lines based on natural frequency spectrum of current measurements. Unlike traditional protection schemes relying on derivatives of traveling waves, boundary voltage characteristics or transient energies, the proposed method derives the mathematical expression and the natural frequencies of measured currents in detail. By comparing these theoretical peaks with the actual measured peak frequencies which are obtained via the MUSIC algorithm, internal faults can be distinguished from external ones. The method requires only single-ended current measurements, and avoids ultra-high sampling rates. Simulation results prove that the proposed method is valid under different fault locations and resistances.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2026-02-19
DOI
https://doi.org/10.1049/icp.2025.3985
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-ended protection method based on spectrum of natural frequency for lines in MMC-HVDC grids

Ying Liu, Zhiquan Liu, Ruiyu Pan, Yu Liu
IET conference proceedings.
HVDC Systems and Fault Protection
article

Single-ended protection method based on spectrum of natural frequency for lines in MMC-HVDC grids

Ying Liu, Zhiquan Liu, Ruiyu Pan, Yu Liu
article en

Abstract

This paper proposes an improved single-ended protection method for Modular Multilevel Converter-based High Voltage Direct Current (MMC-HVDC) lines based on natural frequency spectrum of current measurements. Unlike traditional protection schemes relying on derivatives of traveling waves, boundary voltage characteristics or transient energies, the proposed method derives the mathematical expression and the natural frequencies of measured currents in detail. By comparing these theoretical peaks with the actual measured peak frequencies which are obtained via the MUSIC algorithm, internal faults can be distinguished from external ones. The method requires only single-ended current measurements, and avoids ultra-high sampling rates. Simulation results prove that the proposed method is valid under different fault locations and resistances.

IET conference proceedings.Vol. 2025(38)
ShanghaiTech University (CN)
Affordable and clean energy
Openalex Percentile: Top 50%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Single-ended protection method based on spectrum of natural frequency for lines in MMC-HVDC grids — Ying Liu, Zhiquan Liu, et al. · IET conference proceedings. (2026) | TGRS Research Map | TGRS