Automated Single-Sensor 3D Scanning and Modular Benchmark Objects for Human-Scale 3D Reconstruction
High-fidelity 3D reconstruction of human-sized objects typically requires multi-sensor scanning systems that are expensive, complex, and rely on proprietary hardware configurations. Existing low-cost approaches often rely on handheld scanning, which is inherently unstructured and operator-dependent, leading to inconsistent coverage and variable reconstruction quality. This limitation necessitates the need for a controlled, repeatable, and affordable scanning method that can generate high-quality data without requiring multi-sensor hardware or external tracking markers. This study presents a marker-less scanning platform designed for human-scale reconstruction. The system consists of a single structured-light sensor mounted on a vertical linear actuator, synchronised with a motorised turntable that rotates the subject. This constrained kinematic setup ensures a repeatable cylindrical acquisition trajectory. To address the geometric ambiguity often found in vertical translational symmetry (i.e., where distinct elevation steps appear identical), the system employs a sensor-assisted initialisation strategy, where feedback from the rotary encoder and linear drive serves as constraints for the registration pipeline. The captured frames are reconstructed into a complete model through a two-step Iterative Closest Point (ICP) procedure that eliminates the vertical drift and model collapse (often referred to as "telescoping") common in unconstrained scanning. To evaluate system performance, a modular anthropometric benchmark object representing a human-sized target (1.6 m) was scanned. The reconstructed model was assessed in terms of surface coverage and volumetric fidelity relative to a CAD reference. The results demonstrate high sampling stability, achieving a mean surface density of 0.760points/mm2 on front-facing surfaces. Geometric deviation analysis revealed a mean signed error of -1.54 mm (σ= 2.27 mm), corresponding to a relative volumetric error of approximately 0.096% over the full vertical span. These findings confirm that a single-sensor system, when guided by precise kinematics, can mitigate the non-linear bending and drift artefacts of handheld acquisition, providing an accessible yet rigorously accurate alternative to industrial multi-sensor systems.
Authors
- Mats Isaksson (ORCID: https://orcid.org/0000-0003-3047-6811)
- G. Lambert
- Kartik Choudhary
- Tony Dicker
Institutions
- The University of Queensland (AU)
- Swinburne University of Technology (AU)
Publication Details
- Journal
- Sensors
- Published
- 2026-02-19
- DOI
- https://doi.org/10.3390/s26041331
- Primary Topic
- 3D Shape Modeling and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00