Fast-scale instability analysis of valley-current-mode controlled buck converter with high-frequency pulsed current load

In a DC distribution power system, the input current of post-stage converter can be regarded as a high-frequency pulsed current load (HFPCL) of pre-stage converter. Different from the traditional resistive load, HFPCL is a type of periodic and time-varying load and its frequency is around the switching frequency of the pre-stage converter. To reveal the fast-scale instability induced by the HFPCL, a valley current mode (VCM) controlled buck converter is taken as the pre-stage converter. First, the fast-scale instabilities in the VCM controlled buck converter with HFPCL are shown by the bifurcation diagrams. Second, an equivalent model of the VCM controlled buck converter with HFPCL is built up. Third, by utilizing Filippov's method and Floquet theory, the monodromy matrix of the equivalent model is obtained and the corresponding eigenvalue analyses are carried out. The results manifest that under HFPCL, the stability effects of the circuit parameters of front-stage converter can be significantly changed. Finally, the correctness of the theoretical and simulation results is confirmed by the experimental results.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2026-02-19
DOI
https://doi.org/10.1049/icp.2025.3941
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast-scale instability analysis of valley-current-mode controlled buck converter with high-frequency pulsed current load

L. Wang, Rongxin Xia, Xi Zhang, Ren Sun
IET conference proceedings.
Advanced DC-DC Converters
article

Fast-scale instability analysis of valley-current-mode controlled buck converter with high-frequency pulsed current load

L. Wang, Rongxin Xia, Xi Zhang, Ren Sun
article en

Abstract

In a DC distribution power system, the input current of post-stage converter can be regarded as a high-frequency pulsed current load (HFPCL) of pre-stage converter. Different from the traditional resistive load, HFPCL is a type of periodic and time-varying load and its frequency is around the switching frequency of the pre-stage converter. To reveal the fast-scale instability induced by the HFPCL, a valley current mode (VCM) controlled buck converter is taken as the pre-stage converter. First, the fast-scale instabilities in the VCM controlled buck converter with HFPCL are shown by the bifurcation diagrams. Second, an equivalent model of the VCM controlled buck converter with HFPCL is built up. Third, by utilizing Filippov's method and Floquet theory, the monodromy matrix of the equivalent model is obtained and the corresponding eigenvalue analyses are carried out. The results manifest that under HFPCL, the stability effects of the circuit parameters of front-stage converter can be significantly changed. Finally, the correctness of the theoretical and simulation results is confirmed by the experimental results.

IET conference proceedings.Vol. 2025(38)
Changzhou University (CN), Chongqing Three Gorges University (CN)
Openalex Percentile: Top 50%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fast-scale instability analysis of valley-current-mode controlled buck converter with high-frequency pulsed current load — L. Wang, Rongxin Xia, et al. · IET conference proceedings. (2026) | TGRS Research Map | TGRS