Deep Learning Automated Measurement of Shunt Severity with Estimation of Uncertainty in 4D Flow MRI

Purpose To assess the feasibility of a deep learning (DL) system to fully automate systemic and pulmonary blood flow measurement with four-dimensional (4D) flow MRI. Materials and Methods A total of 188 clinical 4D flow MRI examinations were retrospectively collected to develop a DL system that serially performs (<i>a)</i> three-dimensional localization and <i>(b)</i> two-dimensional segmentation to compute net aortic and pulmonary artery flow. For each vessel, the system computes the means and SDs (σ) across multiple locations. In a separate composite population of 71 patients with and without shunts, automated and manual measurements from trained physicians were compared with ground truth measurements from a senior radiologist using Pearson correlation and Bland-Altman analysis. Results Automated aortic and pulmonary artery flow estimates and shunt fraction calculations were performed in all 71 patients. Correlation with ground truth was strong (ρ = 0.832, 0.863, and 0.861, respectively; <i>P</i> < .001) with low mean bias (0.40 L/min, 0.20 L/min, and -0.10). High certainty (σ < 0.5 L/min) was observed in 83% (59 of 71) of aortic, 75% (53 of 71) of pulmonary, and 65% (46 of 71) of both aortic and pulmonary flow measurements. Within these subsets, correlations improved (ρ = 0.881, 0.989, and 0.948; <i>P</i> < .001) and closely matched expert readers. Conclusion A DL system can automatically measure blood flow from 4D flow MRI with accuracy comparable to that of trained physicians. <b>Keywords:</b> Deep Learning, Congenital Heart Disease, Shunt Severity, 4D Flow MRI, Convolutional Neural Networks <i>Supplemental material is available for this article.</i> © RSNA, 2026.

Authors

Institutions

Publication Details

Journal
Radiology Cardiothoracic Imaging
Published
2026-02-01
DOI
https://doi.org/10.1148/ryct.250138
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning Automated Measurement of Shunt Severity with Estimation of Uncertainty in 4D Flow MRI

Roshun Sankaran, Evan Masutani, Arielle K. Tycko, Lily Sung et al.
Radiology Cardiothoracic Imaging
Hemodynamic Monitoring and Therapy
article

Deep Learning Automated Measurement of Shunt Severity with Estimation of Uncertainty in 4D Flow MRI

Roshun Sankaran, Evan Masutani, Arielle K. Tycko, Lily Sung, Albert Hsiao, Noe Cazares, Parker M. Rushworth, Kent M. Hall, Akhilesh R. R. Yeluru
article en

Abstract

Purpose To assess the feasibility of a deep learning (DL) system to fully automate systemic and pulmonary blood flow measurement with four-dimensional (4D) flow MRI. Materials and Methods A total of 188 clinical 4D flow MRI examinations were retrospectively collected to develop a DL system that serially performs (<i>a)</i> three-dimensional localization and <i>(b)</i> two-dimensional segmentation to compute net aortic and pulmonary artery flow. For each vessel, the system computes the means and SDs (σ) across multiple locations. In a separate composite population of 71 patients with and without shunts, automated and manual measurements from trained physicians were compared with ground truth measurements from a senior radiologist using Pearson correlation and Bland-Altman analysis. Results Automated aortic and pulmonary artery flow estimates and shunt fraction calculations were performed in all 71 patients. Correlation with ground truth was strong (ρ = 0.832, 0.863, and 0.861, respectively; <i>P</i> < .001) with low mean bias (0.40 L/min, 0.20 L/min, and -0.10). High certainty (σ < 0.5 L/min) was observed in 83% (59 of 71) of aortic, 75% (53 of 71) of pulmonary, and 65% (46 of 71) of both aortic and pulmonary flow measurements. Within these subsets, correlations improved (ρ = 0.881, 0.989, and 0.948; <i>P</i> < .001) and closely matched expert readers. Conclusion A DL system can automatically measure blood flow from 4D flow MRI with accuracy comparable to that of trained physicians. <b>Keywords:</b> Deep Learning, Congenital Heart Disease, Shunt Severity, 4D Flow MRI, Convolutional Neural Networks <i>Supplemental material is available for this article.</i> © RSNA, 2026.

Radiology Cardiothoracic ImagingVol. 8(1)
University of California, Irvine (US), University of California San Diego (US), Naval Hospital Pensacola (US), University of California San Diego Medical Center (US), La Jolla Bioengineering Institute (US), Irvine University (US), Wake Forest University (US)
Openalex Percentile: Top 50%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.