Efficacy and safety of pulsed field ablation versus conventional thermal techniques for patients with atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials

Atrial fibrillation (AF) is the most common cardiac arrhythmia and a leading cause of stroke. Pulsed field ablation (PFA) emerges as a novel, non-thermal energy source offering myocardial-selective ablation with a potentially improved safety and efficacy profile. To compare the safety and efficacy of PFA versus RFA/CBA ablation in patients with AF. Multiple databases were systematically searched from inception to May 2025. Randomized Controlled Trials (RCTs) comparing PFA versus thermal ablation (TA) were analyzed using risk ratio (RR) and mean difference (MD) with 95% Confidence Intervals (CI). Random-effects model was employed to account for heterogeneity, as measured by I2 and quantified using leave-one-out analysis. We included 1,294 patients, of whom 653 (50.4%) underwent PFA from four RCTs. Among the included patients, 62.4% have hypertension and a CHA2DS2-VASc mean score of 2.0 ± 1.4. In the pooled analysis, no significant differences were found between PFA group when compared to TA regarding treatment success (RR = 1.11; 95% CI 0.87–1.42; ρ = 0.20), serious adverse events (RR = 1.24; 95% CI 0.38–4.09; ρ = 0.51), recurrent atrial arrhythmias (RR = 0.86; 95% CI 0.54–1.38; ρ = 0.31), and repeat ablation (RR = 0.89; 95% CI 0.18–4.38; ρ = 0.78). However, the procedural time (MD = -38.80 min; 95% CI -75.52–2.08; ρ = 0.04) was significantly reduced in patients who underwent PFA. PFA appears comparable to radiofrequency and cryoballoon ablation for atrial fibrillation, with shorter procedure times but similar efficacy and complication rates. Given that most outcomes were graded as low or very low certainty, further large, long-term randomized trials are needed to confirm these findings.

Authors

Institutions

Publication Details

Journal
BMC Cardiovascular Disorders
Published
2026-02-19
DOI
https://doi.org/10.1186/s12872-026-05621-2
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and safety of pulsed field ablation versus conventional thermal techniques for patients with atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials

Juliana Giorgi, Julie Mojica, Salomon Chamay, Jasmine Soco Interior et al.
BMC Cardiovascular Disorders
Atrial Fibrillation Management and Outcomes
article

Efficacy and safety of pulsed field ablation versus conventional thermal techniques for patients with atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials

Juliana Giorgi, Julie Mojica, Salomon Chamay, Jasmine Soco Interior, Muhammad Aqib Faizan, Mrunalini Dandamudi, Tooba Rehman, Omar Kasimieh, Navya Mandalapu
article en

Abstract

Atrial fibrillation (AF) is the most common cardiac arrhythmia and a leading cause of stroke. Pulsed field ablation (PFA) emerges as a novel, non-thermal energy source offering myocardial-selective ablation with a potentially improved safety and efficacy profile. To compare the safety and efficacy of PFA versus RFA/CBA ablation in patients with AF. Multiple databases were systematically searched from inception to May 2025. Randomized Controlled Trials (RCTs) comparing PFA versus thermal ablation (TA) were analyzed using risk ratio (RR) and mean difference (MD) with 95% Confidence Intervals (CI). Random-effects model was employed to account for heterogeneity, as measured by I2 and quantified using leave-one-out analysis. We included 1,294 patients, of whom 653 (50.4%) underwent PFA from four RCTs. Among the included patients, 62.4% have hypertension and a CHA2DS2-VASc mean score of 2.0 ± 1.4. In the pooled analysis, no significant differences were found between PFA group when compared to TA regarding treatment success (RR = 1.11; 95% CI 0.87–1.42; ρ = 0.20), serious adverse events (RR = 1.24; 95% CI 0.38–4.09; ρ = 0.51), recurrent atrial arrhythmias (RR = 0.86; 95% CI 0.54–1.38; ρ = 0.31), and repeat ablation (RR = 0.89; 95% CI 0.18–4.38; ρ = 0.78). However, the procedural time (MD = -38.80 min; 95% CI -75.52–2.08; ρ = 0.04) was significantly reduced in patients who underwent PFA. PFA appears comparable to radiofrequency and cryoballoon ablation for atrial fibrillation, with shorter procedure times but similar efficacy and complication rates. Given that most outcomes were graded as low or very low certainty, further large, long-term randomized trials are needed to confirm these findings.

BMC Cardiovascular DisordersVol. 26(1)
Bronx-Lebanon Hospital Center (US), Mapúa University (PH), Gomal University (PK), Hospital Israelita Albert Einstein (BR), University of the East Ramon Magsaysay Memorial Medical Center (PH), St. Barnabas Hospital (US), Montefiore Hospital (GB), Hospital Sírio-Libanês (BR)
Good health and well-being
Openalex Percentile: Top 54%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.