Standardizing Perioperative Heat to Improve Mouse (Mus musculus) Recovery

Maintaining the core body temperature of anesthetized rodents is essential because of the depression of physiologic homeostasis caused by anesthetics. The maintenance of core body temperature is influenced by the ability of the heating device to provide sufficient heat, the presence of material that might alter heat transfer, and the administration of heat in the period surrounding anesthesia. In this study, optimal heat transfer from 4 unique heating devices, with or without insulating drapes, was determined initially with an inert model. Optimal animal recovery, as evaluated by recovery to baseline activity and normothermic temperature of postoperative animals implanted with an intrabdominal thermometer and monitored with a digitally ventilated caging, was achieved by a device that provided consistent electrically supplied heat at 40 °C throughout the perianesthesia period including 35 minutes before isoflurane anesthetic induction. Animals without preoperative heating required at least 24 hours to return to normal core temperature and normal circadian activity levels.

Authors

Institutions

Publication Details

Journal
Journal of the American Association for Laboratory Animal Science
Published
2026-02-01
DOI
https://doi.org/10.30802/aalas-jaalas-25-173
Primary Topic
Veterinary Pharmacology and Anesthesia
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standardizing Perioperative Heat to Improve Mouse (Mus musculus) Recovery

Julita A Ramirez, Stephanie Oldham, Bhanvi Mishra, Erin Straley et al.
Journal of the American Association for Laboratory Animal Science
Veterinary Pharmacology and Anesthesia
article

Standardizing Perioperative Heat to Improve Mouse (Mus musculus) Recovery

Julita A Ramirez, Stephanie Oldham, Bhanvi Mishra, Erin Straley, Seo-Kyoung Hwang, Robin J Kastenmayer, Xiaokang Luo, Andrew J Popadich
article en

Abstract

Maintaining the core body temperature of anesthetized rodents is essential because of the depression of physiologic homeostasis caused by anesthetics. The maintenance of core body temperature is influenced by the ability of the heating device to provide sufficient heat, the presence of material that might alter heat transfer, and the administration of heat in the period surrounding anesthesia. In this study, optimal heat transfer from 4 unique heating devices, with or without insulating drapes, was determined initially with an inert model. Optimal animal recovery, as evaluated by recovery to baseline activity and normothermic temperature of postoperative animals implanted with an intrabdominal thermometer and monitored with a digitally ventilated caging, was achieved by a device that provided consistent electrically supplied heat at 40 °C throughout the perianesthesia period including 35 minutes before isoflurane anesthetic induction. Animals without preoperative heating required at least 24 hours to return to normal core temperature and normal circadian activity levels.

Journal of the American Association for Laboratory Animal Science
AstraZeneca (United States) (US)
Openalex Percentile: Top 49%
Veterinary Pharmacology and Anesthesia
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.