Simultaneous electrochemical detection of imipenem and meropenem using a Pt–Au bimetallic nanoparticle–decorated 3D graphene oxide modified glassy carbon electrode

The goal of this study was to create a low-cost, simultaneous, and sensitive electrochemical sensor for detecting the imipenem and meropenem. In order to determine them simultaneously, the first electrochemical sensor was created by combining a glassy carbon electrode (GCE) with a nanocomposite made of platinum-gold bimetallic nanoparticle-decorated three-dimensional graphene oxide (Pt-Au Bm-NPs/3D GO). Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to evaluate the surface of Pt-Au Bm-NPs/3D GO/GCE. imipenem's electrochemical signals increased as a result of the improvement of many sensitivity-affecting factors, including pH, electrode composition, and scan rate. The analysis of the CV data revealed that imipenem's and meropenem's redox were completely irreversible reactions. Chronoamperometry was utilized to ascertain the imipenem's and meropenem's diffusion coefficients (1.25 ± 0.02 × 10<sup>- 5</sup> cm<sup>2</sup>s<sup>- 1</sup> and 5.24 ± 0.02 × 10<sup>- 5</sup> cm<sup>2</sup>s<sup>- 1</sup>, respectively). The imipenem and meropenem linear dynamic ranges were 0.001-800.0 µM with detection limits of 0.18 nM and 0.14 nM, respectively. Additionally, for the electrochemical oxidation of imipenem and meropenem, the DPV findings revealed two well-resolved anodic waves with a peak separation of around 230 mV, allowing for the simultaneous identification of both chemicals. It is very appropriate for detecting imipenem and meropenem in real samples because to its high sensitivity, low detection limit (nanomolar), remarkable repeatability, and ease of manufacture and renewal of the electrode.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-19
DOI
https://doi.org/10.1038/s41598-026-36658-0
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous electrochemical detection of imipenem and meropenem using a Pt–Au bimetallic nanoparticle–decorated 3D graphene oxide modified glassy carbon electrode

Mehran Moradalizadeh, Mohammad Mehdi Foroughi, Shohreh Jahani, Hossein Jamali Paghaleh
Scientific Reports
Antibiotics Pharmacokinetics and Efficacy
article

Simultaneous electrochemical detection of imipenem and meropenem using a Pt–Au bimetallic nanoparticle–decorated 3D graphene oxide modified glassy carbon electrode

Mehran Moradalizadeh, Mohammad Mehdi Foroughi, Shohreh Jahani, Hossein Jamali Paghaleh
article en

Abstract

The goal of this study was to create a low-cost, simultaneous, and sensitive electrochemical sensor for detecting the imipenem and meropenem. In order to determine them simultaneously, the first electrochemical sensor was created by combining a glassy carbon electrode (GCE) with a nanocomposite made of platinum-gold bimetallic nanoparticle-decorated three-dimensional graphene oxide (Pt-Au Bm-NPs/3D GO). Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to evaluate the surface of Pt-Au Bm-NPs/3D GO/GCE. imipenem's electrochemical signals increased as a result of the improvement of many sensitivity-affecting factors, including pH, electrode composition, and scan rate. The analysis of the CV data revealed that imipenem's and meropenem's redox were completely irreversible reactions. Chronoamperometry was utilized to ascertain the imipenem's and meropenem's diffusion coefficients (1.25 ± 0.02 × 10<sup>- 5</sup> cm<sup>2</sup>s<sup>- 1</sup> and 5.24 ± 0.02 × 10<sup>- 5</sup> cm<sup>2</sup>s<sup>- 1</sup>, respectively). The imipenem and meropenem linear dynamic ranges were 0.001-800.0 µM with detection limits of 0.18 nM and 0.14 nM, respectively. Additionally, for the electrochemical oxidation of imipenem and meropenem, the DPV findings revealed two well-resolved anodic waves with a peak separation of around 230 mV, allowing for the simultaneous identification of both chemicals. It is very appropriate for detecting imipenem and meropenem in real samples because to its high sensitivity, low detection limit (nanomolar), remarkable repeatability, and ease of manufacture and renewal of the electrode.

Scientific ReportsVol. 16(1)
Bam University of Medical Sciences (IR), Islamic Azad University Kerman (IR)
Islamic Azad University
Openalex Percentile: Top 50%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.