A TOPAS-based simulation and reconstruction framework for sparse-view 2D photon dosimetry with scintillating optical fibers

Tomodosimetry employs arrays of scintillating optical fibers to measure 2D or 3D dose distributions with high spatial resolution, making it promising for experimental validations in conformal radiotherapy. However, several aspects remain insufficiently explored, including the effects of scattered and Cherenkov radiation, the consequences of limited angular sampling, and the spatial resolution as a function of the detector design. In this work, we developed a numerical framework to evaluate the performance of a tomodosimeter under such constraints, aiming to preserve dose reconstruction quality while minimizing the number of projections. The proposed formalism incorporates both scattered and Cherenkov radiation, enabling accurate derivation of 2D dose distributions by calibrating scintillating fibers in terms of dose integral in water. Through Monte Carlo simulations of a BCF-60 fiber-based tomodosimeter, we assessed how design features, angular sampling limitations, and reconstruction methods affect the quality of reconstructed IMRT segment doses. Our results show that, even with only six projections, we achieved a 98.8% success rate of the 3%/3 mm gamma test between the reconstruction of the IMRT segment dose distribution, and the reference dose distribution. Additionally, the limiting spatial resolution of the fibers-in-contact configuration was found to be 1.53 mm, based on the 10% modulation of the oversampled modulation transfer function. These findings demonstrate that accurate and high-resolution tomodosimetric dose reconstructions are feasible with a reduced number of projections, offering a significant step forward in accelerating the clinical integration of this technology. • A novel simulation and reconstruction framework for tomodosimetry is reported. • Imaging properties of a 2D scintillating fiber array are derived. • Spatial resolution limit of 1.53 mm achieved with 1 mm BCF-60 fibers in contact. • Iterative reconstruction achieves 98.8% gamma test success with only 6 projections.

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2026-02-19
DOI
https://doi.org/10.1016/j.radmeas.2026.107648
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A TOPAS-based simulation and reconstruction framework for sparse-view 2D photon dosimetry with scintillating optical fibers

A. Martı́nez-Dávalos, Eduardo Martinez-Lopez
Radiation Measurements
Advanced Radiotherapy Techniques
article

A TOPAS-based simulation and reconstruction framework for sparse-view 2D photon dosimetry with scintillating optical fibers

A. Martı́nez-Dávalos, Eduardo Martinez-Lopez
article en

Abstract

Tomodosimetry employs arrays of scintillating optical fibers to measure 2D or 3D dose distributions with high spatial resolution, making it promising for experimental validations in conformal radiotherapy. However, several aspects remain insufficiently explored, including the effects of scattered and Cherenkov radiation, the consequences of limited angular sampling, and the spatial resolution as a function of the detector design. In this work, we developed a numerical framework to evaluate the performance of a tomodosimeter under such constraints, aiming to preserve dose reconstruction quality while minimizing the number of projections. The proposed formalism incorporates both scattered and Cherenkov radiation, enabling accurate derivation of 2D dose distributions by calibrating scintillating fibers in terms of dose integral in water. Through Monte Carlo simulations of a BCF-60 fiber-based tomodosimeter, we assessed how design features, angular sampling limitations, and reconstruction methods affect the quality of reconstructed IMRT segment doses. Our results show that, even with only six projections, we achieved a 98.8% success rate of the 3%/3 mm gamma test between the reconstruction of the IMRT segment dose distribution, and the reference dose distribution. Additionally, the limiting spatial resolution of the fibers-in-contact configuration was found to be 1.53 mm, based on the 10% modulation of the oversampled modulation transfer function. These findings demonstrate that accurate and high-resolution tomodosimetric dose reconstructions are feasible with a reduced number of projections, offering a significant step forward in accelerating the clinical integration of this technology. • A novel simulation and reconstruction framework for tomodosimetry is reported. • Imaging properties of a 2D scintillating fiber array are derived. • Spatial resolution limit of 1.53 mm achieved with 1 mm BCF-60 fibers in contact. • Iterative reconstruction achieves 98.8% gamma test success with only 6 projections.

Radiation MeasurementsVol. 193
Universidad Autónoma de la Ciudad de México (MX), Universidad Nacional Autónoma de México (MX)
Openalex Percentile: Top 44%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.