Analysis of single-channel and canopy-to-canopy cold plate cooling systems under cyclic operation

• Single-channel and canopy-to-canopy cold plates are tested under cyclic operation. • A cooling strategy based on controlled pumping activation is developed. • The cycle time is evaluated experimentally and numerically for all configurations. • A correlation relating cycle time to the conduction/convection ratio is proposed. • An additional cold plate is designed and tested to validate the correlation. The performance of PEM fuel cells strongly depends on the operating temperature, being negatively impacted when the equipment works outside of a prescribed temperature range. In this work, a novel liquid-based cooling approach is proposed to keep the average temperature of the heated plate within a temperature range with minimum energy consumption. The strategy consists in switching the coolant pumping on when the average temperature of the cold plate reaches the upper limit of the temperature range, and turning it off once the average temperature coincides with the lower limit. Four canopy-to-canopy and five single-channel configurations are experimentally and numerically tested for three different values of the pumping power. The maximum deviation of the cycle time (plate heating followed by cooling) between the experimental measurements and the numerical simulations is 8 % for all configurations, confirming the validity of the numerical approach. Among the tested designs, canopy-to-canopy configurations with four or more branches exhibit the shortest cycle time under all studied conditions, in both experiments and simulations. The cycle time was found to describe a linear relation with the ratio between conduction in the cold plate and convection in the channel, i.e., distance to the channel and coolant mass flow rate. An additional single-channel configuration was designed and built specifically to test the validity of the linear correlations derived, estimating the cycle time with theoretical, numerical and experimental calculations for the coolant mass flow rate. The deviation between these predictions and the experimentally measured cycle time is below 5 % for all cases.

Authors

Institutions

Publication Details

Journal
International Journal of Heat and Mass Transfer
Published
2026-02-19
DOI
https://doi.org/10.1016/j.ijheatmasstransfer.2026.128545
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of single-channel and canopy-to-canopy cold plate cooling systems under cyclic operation

Sylvie Lorente, José Félix Guil-Pedrosa, L.M. García-Gutiérrez, Antonio Soria-Verdugo
International Journal of Heat and Mass Transfer
Heat Transfer and Optimization
article

Analysis of single-channel and canopy-to-canopy cold plate cooling systems under cyclic operation

Sylvie Lorente, José Félix Guil-Pedrosa, L.M. García-Gutiérrez, Antonio Soria-Verdugo
article en

Abstract

• Single-channel and canopy-to-canopy cold plates are tested under cyclic operation. • A cooling strategy based on controlled pumping activation is developed. • The cycle time is evaluated experimentally and numerically for all configurations. • A correlation relating cycle time to the conduction/convection ratio is proposed. • An additional cold plate is designed and tested to validate the correlation. The performance of PEM fuel cells strongly depends on the operating temperature, being negatively impacted when the equipment works outside of a prescribed temperature range. In this work, a novel liquid-based cooling approach is proposed to keep the average temperature of the heated plate within a temperature range with minimum energy consumption. The strategy consists in switching the coolant pumping on when the average temperature of the cold plate reaches the upper limit of the temperature range, and turning it off once the average temperature coincides with the lower limit. Four canopy-to-canopy and five single-channel configurations are experimentally and numerically tested for three different values of the pumping power. The maximum deviation of the cycle time (plate heating followed by cooling) between the experimental measurements and the numerical simulations is 8 % for all configurations, confirming the validity of the numerical approach. Among the tested designs, canopy-to-canopy configurations with four or more branches exhibit the shortest cycle time under all studied conditions, in both experiments and simulations. The cycle time was found to describe a linear relation with the ratio between conduction in the cold plate and convection in the channel, i.e., distance to the channel and coolant mass flow rate. An additional single-channel configuration was designed and built specifically to test the validity of the linear correlations derived, estimating the cycle time with theoretical, numerical and experimental calculations for the coolant mass flow rate. The deviation between these predictions and the experimentally measured cycle time is below 5 % for all cases.

International Journal of Heat and Mass TransferVol. 261
Universidad Carlos III de Madrid (ES), Villanova University (US)
Affordable and clean energy
Openalex Percentile: Top 51%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.