Numerical Simulations of an Under-Ventilated Corridor-like Enclosure Fire

The paper presents computational fluid dynamics (CFD) simulations of a propane-fueled and under-ventilated fire in a reduced-scale corridor-like enclosure. The fire source is positioned at the closed end of the corridor. Due to the restricted inflow of oxygen, the flame lifts off from the gaseous burner and travels—along with unburned fuel—all the way to the open doorway at the opposite end of the corridor. Oxygen calorimetry shows that a quasi-steady state plateau is established, during which the heat release rate (HRR) within the enclosure is equal to the theoretical value Q˙in=1500 AoHo where AoHo is the ventilation factor. Then, external flaming occurs. CFD simulations with the Fire Dynamics Simulator (FDS) captured well the overall flame dynamics. More specifically, the HRR plateau is well predicted, provided that the actual autoignition temperature of propane, AIT = 450 °C, is prescribed instead of the default AIT = −273 °C. However, the occurrence time of external flaming remains significantly underestimated and is better predicted by setting AIT = 600 °C. This aspect of the modelling, linked to extinction and (re-)ignition, remains to be further investigated in the future.

Authors

Institutions

Publication Details

Journal
Fire
Published
2026-02-19
DOI
https://doi.org/10.3390/fire9020091
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Simulations of an Under-Ventilated Corridor-like Enclosure Fire

Tarek Beji, Omar Khayyat
Fire
Fire dynamics and safety research
article

Numerical Simulations of an Under-Ventilated Corridor-like Enclosure Fire

Tarek Beji, Omar Khayyat
article en

Abstract

The paper presents computational fluid dynamics (CFD) simulations of a propane-fueled and under-ventilated fire in a reduced-scale corridor-like enclosure. The fire source is positioned at the closed end of the corridor. Due to the restricted inflow of oxygen, the flame lifts off from the gaseous burner and travels—along with unburned fuel—all the way to the open doorway at the opposite end of the corridor. Oxygen calorimetry shows that a quasi-steady state plateau is established, during which the heat release rate (HRR) within the enclosure is equal to the theoretical value Q˙in=1500 AoHo where AoHo is the ventilation factor. Then, external flaming occurs. CFD simulations with the Fire Dynamics Simulator (FDS) captured well the overall flame dynamics. More specifically, the HRR plateau is well predicted, provided that the actual autoignition temperature of propane, AIT = 450 °C, is prescribed instead of the default AIT = −273 °C. However, the occurrence time of external flaming remains significantly underestimated and is better predicted by setting AIT = 600 °C. This aspect of the modelling, linked to extinction and (re-)ignition, remains to be further investigated in the future.

FireVol. 9(2)
Ghent University (BE)
Universiteit Gent
Sustainable cities and communities
Openalex Percentile: Top 60%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.