Using <scp>PBPK</scp> to Simulate Target Biopredictive Dissolution Profiles for Long‐Acting Injectables ‐ Where to Begin With Critical Bioavailability Attributes?

Long-acting injectables (LAI) are of increasing interest as they facilitate improved medication adherence and exposure, with target plasma concentration levels maintained over weeks/months. Biopredictive in vitro dissolution tests can aid formulation development of LAIs and guide quality control dissolution testing by facilitating accelerated test development. However, it is not easy to develop such tests when mechanisms underlying in vivo dissolution are not fully understood. The question of interest (QOI) and context of use (COU) of this study involve quantifying the impact of in vivo parameters which are critical bioavailability attributes (CBAs), using physiologically based pharmacokinetic (PBPK) models generated for LAI methylprednisolone acetate. Simulated dissolution profiles from the PBPK models can provide a design space for biopredictive in vitro dissolution testing methods. The five CBAs explored in this study were particle size, solubility, diffusion layer thickness, diffusion coefficient, and depot volume. Although the best performing models displayed good predictive ability, they used different (literature/prediction derived) attribute values. Simulated in vivo dissolution profiles generated suggested much slower dissolution rates, with 80-100% dissolved after 1200 h, than in vitro dissolution tests from FDA 'Dissolution Methods Database,' where almost 90% was dissolved in 90 min. To conclude, in vitro dissolution conditions resulting in larger effective particle sizes and diffusion layer thickness, suggesting low fluid velocities, need to be explored to generate biopredictive dissolution profiles. The current approach illustrates how using models with plausible CBA value ranges can be used to simulate a target dissolution profile design space, assisting in vitro LAI dissolution test development.

Authors

Institutions

Publication Details

Journal
CPT Pharmacometrics & Systems Pharmacology
Published
2026-02-18
DOI
https://doi.org/10.1002/psp4.70212
Primary Topic
Drug Solubulity and Delivery Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using PBPK to Simulate Target Biopredictive Dissolution Profiles for Long‐Acting Injectables ‐ Where to Begin With Critical Bioavailability Attributes?

Tim Persoons, Deirdre M. D’Arcy, Nikoletta Fotaki, Hannah Cleary
CPT Pharmacometrics & Systems Pharmacology
Drug Solubulity and Delivery Systems
article

Using PBPK to Simulate Target Biopredictive Dissolution Profiles for Long‐Acting Injectables ‐ Where to Begin With Critical Bioavailability Attributes?

Tim Persoons, Deirdre M. D’Arcy, Nikoletta Fotaki, Hannah Cleary
article en

Abstract

Long-acting injectables (LAI) are of increasing interest as they facilitate improved medication adherence and exposure, with target plasma concentration levels maintained over weeks/months. Biopredictive in vitro dissolution tests can aid formulation development of LAIs and guide quality control dissolution testing by facilitating accelerated test development. However, it is not easy to develop such tests when mechanisms underlying in vivo dissolution are not fully understood. The question of interest (QOI) and context of use (COU) of this study involve quantifying the impact of in vivo parameters which are critical bioavailability attributes (CBAs), using physiologically based pharmacokinetic (PBPK) models generated for LAI methylprednisolone acetate. Simulated dissolution profiles from the PBPK models can provide a design space for biopredictive in vitro dissolution testing methods. The five CBAs explored in this study were particle size, solubility, diffusion layer thickness, diffusion coefficient, and depot volume. Although the best performing models displayed good predictive ability, they used different (literature/prediction derived) attribute values. Simulated in vivo dissolution profiles generated suggested much slower dissolution rates, with 80-100% dissolved after 1200 h, than in vitro dissolution tests from FDA 'Dissolution Methods Database,' where almost 90% was dissolved in 90 min. To conclude, in vitro dissolution conditions resulting in larger effective particle sizes and diffusion layer thickness, suggesting low fluid velocities, need to be explored to generate biopredictive dissolution profiles. The current approach illustrates how using models with plausible CBA value ranges can be used to simulate a target dissolution profile design space, assisting in vitro LAI dissolution test development.

CPT Pharmacometrics & Systems PharmacologyVol. 15(3)
Trinity College Dublin (IE), University of Bath (GB)
Science Foundation Ireland, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 50%
Drug Solubulity and Delivery Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.