Development and Evaluation of a Lyophilized Plasma-Based Internal Quality Control for Human Immunodeficiency Virus Rapid Diagnostic Tests

<b>Background/Objectives:</b> Rapid diagnostic tests (RDTs) for human immunodeficiency virus (HIV) are widely used, but most kits lack standardized internal quality control (IQC) materials. In this study, we aimed to develop and evaluate a plasma-based IQC compatible with five HIV RDT brands and with proven long-term stability. <b>Methods:</b> Control samples at three reactivity levels were tested with five HIV RDT kits in lyophilized and liquid forms. Lyophilized samples were produced with and without trehalose, whereas liquid samples were prepared with and without StabilZyme™ SELECT Stabilizer (Stabilizer). Accelerated stability testing was performed at 37 °C and 45 °C for 28 days, and the most stable formulation was selected for long-term storage at 4 ± 2 °C and 25 ± 5 °C. Stability was assessed based on test-line visibility and signal intensity. Signal-intensity trends were analyzed using simple linear regression with a <i>t</i>-test on the slope; samples were considered stable when no significant trend was detected (<i>p</i> > 0.05). <b>Results:</b> Reactivity measured using the Elecsys HIV combi PT assay yielded cutoff index (COI) values of 772.65 (1:8) for the strong-positive control and 269.95 (1:25) for the weak-positive control. Trehalose-containing lyophilized samples maintained reactivity under accelerated testing at 37 and 45 °C and for 6 months at 4 ± 2 °C and 25 ± 5 °C, with no significant change in signal intensity (<i>p</i> > 0.05). <b>Conclusions:</b> The plasma-based IQC materials were compatible with all five HIV RDTs, and trehalose-stabilized lyophilized plasma showed high stability, supporting transport and storage without strict cold-chain requirements.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-02-19
DOI
https://doi.org/10.3390/diagnostics16040608
Primary Topic
HIV Research and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Evaluation of a Lyophilized Plasma-Based Internal Quality Control for Human Immunodeficiency Virus Rapid Diagnostic Tests

Wanvisa Treebuphachatsakul, Napaporn Apiratmateekul, Supaporn Suparak, Nam K. Tran et al.
Diagnostics
HIV Research and Treatment
article

Development and Evaluation of a Lyophilized Plasma-Based Internal Quality Control for Human Immunodeficiency Virus Rapid Diagnostic Tests

Wanvisa Treebuphachatsakul, Napaporn Apiratmateekul, Supaporn Suparak, Nam K. Tran, Siriphailin Jomjunyoung, Gerald J. Kost
article en

Abstract

<b>Background/Objectives:</b> Rapid diagnostic tests (RDTs) for human immunodeficiency virus (HIV) are widely used, but most kits lack standardized internal quality control (IQC) materials. In this study, we aimed to develop and evaluate a plasma-based IQC compatible with five HIV RDT brands and with proven long-term stability. <b>Methods:</b> Control samples at three reactivity levels were tested with five HIV RDT kits in lyophilized and liquid forms. Lyophilized samples were produced with and without trehalose, whereas liquid samples were prepared with and without StabilZyme™ SELECT Stabilizer (Stabilizer). Accelerated stability testing was performed at 37 °C and 45 °C for 28 days, and the most stable formulation was selected for long-term storage at 4 ± 2 °C and 25 ± 5 °C. Stability was assessed based on test-line visibility and signal intensity. Signal-intensity trends were analyzed using simple linear regression with a <i>t</i>-test on the slope; samples were considered stable when no significant trend was detected (<i>p</i> > 0.05). <b>Results:</b> Reactivity measured using the Elecsys HIV combi PT assay yielded cutoff index (COI) values of 772.65 (1:8) for the strong-positive control and 269.95 (1:25) for the weak-positive control. Trehalose-containing lyophilized samples maintained reactivity under accelerated testing at 37 and 45 °C and for 6 months at 4 ± 2 °C and 25 ± 5 °C, with no significant change in signal intensity (<i>p</i> > 0.05). <b>Conclusions:</b> The plasma-based IQC materials were compatible with all five HIV RDTs, and trehalose-stabilized lyophilized plasma showed high stability, supporting transport and storage without strict cold-chain requirements.

DiagnosticsVol. 16(4)
Ministry of Public Health (TH), University of Pittsburgh (US), Computational Diagnostics (United States) (US), Department of Medical Sciences (TH), Naresuan University (TH), University of California, Davis (US)
Naresuan University, Ministry of Higher Education, Science, Research and Innovation, Thailand
Good health and well-being
Openalex Percentile: Top 53%
HIV Research and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.