Treatment and Cleaning of Contact Lenses with Plasma-Activated Solutions

The occurrence of contact lens complications caused by inadequate cleaning of the lenses using "All-in-One" contact lens cleaning solutions (CLCSs) represents a medically relevant problem worldwide. This study explores the potential of cold atmospheric plasma (CAP) to enhance the efficacy of CLCSs and address complications from inadequate lens hygiene. It was examined whether exposure to CAP for 1-24 h could boost the antibacterial effects of CLCSs and other solutions, including Milli-Q water (M-QW), physiological saline (NaCl), and Dulbecco's Phosphate Buffered Saline (DPBS). Additionally, the stability of reactive oxygen and nitrogen species (RONS) and their impact on pH immediately after treatment and over 1-4 weeks was assessed. Furthermore, the cleaning efficacy of plasma-activated solutions (PASs) was tested on lipid-coated silicone hydrogel lenses. Results showed that CAP increased RONS concentrations immediately, with elevated levels persisting over time. While no significant improved antibacterial effect was observed against <i>Escherichia coli</i> in CLCSs, CAP treatment generated disinfectant properties in M-QW and NaCl solutions. Importantly, CAP-treated CLCSs significantly improved the cleaning performance on lipid-coated lenses, though M-QW's cleaning ability worsened post-treatment. pH measurements indicated notable decreases in M-QW and NaCl after CAP, whereas buffered solutions like CLCSs and DPBS remained stable. Overall, CAP demonstrates promise for contact lens disinfection and surface modification; however, further research and pre-clinical trials are necessary before clinical application in ophthalmology.

Authors

Institutions

Publication Details

Journal
Pathogens
Published
2026-02-18
DOI
https://doi.org/10.3390/pathogens15020228
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Treatment and Cleaning of Contact Lenses with Plasma-Activated Solutions

Mark Berneburg, Tim Maisch, Stephanie Arndt, Petra Unger et al.
Pathogens
Plasma Applications and Diagnostics
article

Treatment and Cleaning of Contact Lenses with Plasma-Activated Solutions

Mark Berneburg, Tim Maisch, Stephanie Arndt, Petra Unger, Sigrid Karrer, Julia Spörl
article en

Abstract

The occurrence of contact lens complications caused by inadequate cleaning of the lenses using "All-in-One" contact lens cleaning solutions (CLCSs) represents a medically relevant problem worldwide. This study explores the potential of cold atmospheric plasma (CAP) to enhance the efficacy of CLCSs and address complications from inadequate lens hygiene. It was examined whether exposure to CAP for 1-24 h could boost the antibacterial effects of CLCSs and other solutions, including Milli-Q water (M-QW), physiological saline (NaCl), and Dulbecco's Phosphate Buffered Saline (DPBS). Additionally, the stability of reactive oxygen and nitrogen species (RONS) and their impact on pH immediately after treatment and over 1-4 weeks was assessed. Furthermore, the cleaning efficacy of plasma-activated solutions (PASs) was tested on lipid-coated silicone hydrogel lenses. Results showed that CAP increased RONS concentrations immediately, with elevated levels persisting over time. While no significant improved antibacterial effect was observed against <i>Escherichia coli</i> in CLCSs, CAP treatment generated disinfectant properties in M-QW and NaCl solutions. Importantly, CAP-treated CLCSs significantly improved the cleaning performance on lipid-coated lenses, though M-QW's cleaning ability worsened post-treatment. pH measurements indicated notable decreases in M-QW and NaCl after CAP, whereas buffered solutions like CLCSs and DPBS remained stable. Overall, CAP demonstrates promise for contact lens disinfection and surface modification; however, further research and pre-clinical trials are necessary before clinical application in ophthalmology.

PathogensVol. 15(2)
University Hospital Regensburg (DE)
Openalex Percentile: Top 51%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.