Detection of volatile organic compounds associated with E. coli using headspace correlation gas chromatography

A dynamic headspace correlation gas chromatography (HS-cGC) approach to detect volatile organic compounds associated with Escherichia coli (E. coli) in nutrient broth is described. E. coli identification was achieved by detecting microbial volatile organic compounds (mVOCs) produced by the bacteria in the sample matrix. Headspace of the test solution was introduced into the separation column up to 256 times in a single analysis using a pseudo-random binary modulation sequence (PRBS). A convoluted chromatogram was recorded and later cross-correlated with the injection pattern to generate a correlogram. Inoculated samples starting from single cell inoculum were distinguished from sterile controls after 11 h enrichment. Conventional culture-based plating methods need analysis time on the order of days, but HS-cGC reduced the time-to-detection by approximately one-full day compared to culture-based plating methods. Quantitative comparison of key figures of merit between dynamic HS-cGC and static headspace-comprehensive two-dimensional gas chromatography (HS-GC × GC) is also presented. Here mixed standards were analysed to determine linearity, method detection limit (MDL), limit of quantification (LOQ), and repeatability. The correlation technique demonstrated MDL in the range of 0.5 to 2.0 mg/L and LOQ 2.0 to 5.5 mg/L for the target compounds. These results surpassed the static HS-GC × GC which exhibited a higher MDL (20 to 40 mg/L) and LOQ (80 to 150 mg/L), with comparable linearity and repeatability. With analytical figures of merit 20-40 times better (lower MDL and LOQ) than the previously described GC × GC approach, the HS-cGC methodology is an attractive alternative for trace target analyte determination. HS-cGC has a high potential to complement conventional culture-based plating methods to ramp up surveillance to detect pathogens and/or spoilage microbes in the food setting.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2026-02-18
DOI
https://doi.org/10.1007/s00216-026-06382-9
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of volatile organic compounds associated with E. coli using headspace correlation gas chromatography

Wan Sin Heng, Robert A. Shellie, Snehal Jadhav, Maiken Ueland
Analytical and Bioanalytical Chemistry
Analytical Chemistry and Chromatography
article

Detection of volatile organic compounds associated with E. coli using headspace correlation gas chromatography

Wan Sin Heng, Robert A. Shellie, Snehal Jadhav, Maiken Ueland
article en

Abstract

A dynamic headspace correlation gas chromatography (HS-cGC) approach to detect volatile organic compounds associated with Escherichia coli (E. coli) in nutrient broth is described. E. coli identification was achieved by detecting microbial volatile organic compounds (mVOCs) produced by the bacteria in the sample matrix. Headspace of the test solution was introduced into the separation column up to 256 times in a single analysis using a pseudo-random binary modulation sequence (PRBS). A convoluted chromatogram was recorded and later cross-correlated with the injection pattern to generate a correlogram. Inoculated samples starting from single cell inoculum were distinguished from sterile controls after 11 h enrichment. Conventional culture-based plating methods need analysis time on the order of days, but HS-cGC reduced the time-to-detection by approximately one-full day compared to culture-based plating methods. Quantitative comparison of key figures of merit between dynamic HS-cGC and static headspace-comprehensive two-dimensional gas chromatography (HS-GC × GC) is also presented. Here mixed standards were analysed to determine linearity, method detection limit (MDL), limit of quantification (LOQ), and repeatability. The correlation technique demonstrated MDL in the range of 0.5 to 2.0 mg/L and LOQ 2.0 to 5.5 mg/L for the target compounds. These results surpassed the static HS-GC × GC which exhibited a higher MDL (20 to 40 mg/L) and LOQ (80 to 150 mg/L), with comparable linearity and repeatability. With analytical figures of merit 20-40 times better (lower MDL and LOQ) than the previously described GC × GC approach, the HS-cGC methodology is an attractive alternative for trace target analyte determination. HS-cGC has a high potential to complement conventional culture-based plating methods to ramp up surveillance to detect pathogens and/or spoilage microbes in the food setting.

Analytical and Bioanalytical Chemistry
University of Technology Sydney (AU), University of Tasmania (AU), Deakin University (AU), Hypatia of Alexandria Institute for Reflexion and Studies (MA), Separation Systems (United States) (US)
Australian Government, Deakin University
Openalex Percentile: Top 52%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.