Do we bridge the femur to prevent interprosthetic fractures? A survey of 118 consultant orthopaedic surgeons

Background Interprosthetic femoral fractures between ipsilateral total hip arthroplasty and total knee arthroplasty (TKA) represent an increasingly significant clinical challenge, reflecting the growing prevalence of periprosthetic fractures, rising arthroplasty rates, and an ageing population. Biomechanical studies have identified reduced interprosthetic distance and compromised cortical bone quality as key risk factors; however, clinical data guiding prophylactic management strategies—such as femoral bridge plating—remain limited. Methods A survey of 137 orthopaedic surgeons (118 consultants) was conducted to assess current practice and attitudes towards prophylactic femoral bridge plating. Respondents were asked about factors influencing their decision-making—such as interprosthetic distance, bone quality, and implant constraint—as well as their definitions and methods of measuring interprosthetic distance. Results 75% of surgeons would consider prophylactic plating when the interprosthetic distance was less than two cortical diameters. 62% would prophylactically plate if there was less than 60 mm between implants. 12% stated they would never bridge. Poor bone quality (60%), traumatic indications (52%), and higher TKA constraint (31%) increased the likelihood of bridging. Surgeons varied in how they measured implant distance and whether they considered intramedullary cementing an acceptable alternative. 88% of respondents agreed this is an important clinical question, with the majority supporting future research. Conclusion This survey reveals significant variation in current practice regarding prophylactic femoral bridge plating. While many surgeons favour plating in cases of short interprosthetic distances or compromised bone, decision-making is multifactorial. Further clinical research is essential to develop evidence-based guidelines in this challenging area.

Authors

Institutions

Publication Details

Journal
Trauma
Published
2026-02-18
DOI
https://doi.org/10.1177/14604086261418519
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Do we bridge the femur to prevent interprosthetic fractures? A survey of 118 consultant orthopaedic surgeons

Martin Sharrock, Jonathan Nicholas Lamb, William Gibson
Trauma
Orthopaedic implants and arthroplasty
article

Do we bridge the femur to prevent interprosthetic fractures? A survey of 118 consultant orthopaedic surgeons

Martin Sharrock, Jonathan Nicholas Lamb, William Gibson
article en

Abstract

Background Interprosthetic femoral fractures between ipsilateral total hip arthroplasty and total knee arthroplasty (TKA) represent an increasingly significant clinical challenge, reflecting the growing prevalence of periprosthetic fractures, rising arthroplasty rates, and an ageing population. Biomechanical studies have identified reduced interprosthetic distance and compromised cortical bone quality as key risk factors; however, clinical data guiding prophylactic management strategies—such as femoral bridge plating—remain limited. Methods A survey of 137 orthopaedic surgeons (118 consultants) was conducted to assess current practice and attitudes towards prophylactic femoral bridge plating. Respondents were asked about factors influencing their decision-making—such as interprosthetic distance, bone quality, and implant constraint—as well as their definitions and methods of measuring interprosthetic distance. Results 75% of surgeons would consider prophylactic plating when the interprosthetic distance was less than two cortical diameters. 62% would prophylactically plate if there was less than 60 mm between implants. 12% stated they would never bridge. Poor bone quality (60%), traumatic indications (52%), and higher TKA constraint (31%) increased the likelihood of bridging. Surgeons varied in how they measured implant distance and whether they considered intramedullary cementing an acceptable alternative. 88% of respondents agreed this is an important clinical question, with the majority supporting future research. Conclusion This survey reveals significant variation in current practice regarding prophylactic femoral bridge plating. While many surgeons favour plating in cases of short interprosthetic distances or compromised bone, decision-making is multifactorial. Further clinical research is essential to develop evidence-based guidelines in this challenging area.

Trauma
Wrightington Hospital (GB)
Openalex Percentile: Top 51%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.