Integration of EPICS-based remote control and monitoring system for modernization of KAHIF RFQ LLRF system

This technical note describes the modernization of the Low-Level Radio Frequency (LLRF) system for the Radio Frequency Quadrupole (RFQ) accelerator at the Korea Atomic Energy Research Institute Heavy Ion Facility (KAHIF). The legacy LLRF system, operating at 25.95 MHz, relied on manual analog controls, which limited operational efficiency and made fault diagnosis difficult due to its opaque circuit configuration. To address these issues, we integrated key hardware components—including a signal generator, a data acquisition (DAQ) module, and an oscilloscope—into the EPICS (Experimental Physics and Industrial Control System) environment. The upgraded system enables precise remote control with a frequency resolution of 40 Hz and an amplitude resolution of 0.04 dBm. Furthermore, real-time monitoring and archiving of RF waveforms and power parameters have been realized, significantly enhancing the operational stability and maintenance efficiency of the RFQ accelerator.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2026-02-19
DOI
https://doi.org/10.1016/j.net.2026.104206
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of EPICS-based remote control and monitoring system for modernization of KAHIF RFQ LLRF system

Seunghyun Lee, Kihyun Lee, Sangbeen Lee
Nuclear Engineering and Technology
Particle accelerators and beam dynamics
article

Integration of EPICS-based remote control and monitoring system for modernization of KAHIF RFQ LLRF system

Seunghyun Lee, Kihyun Lee, Sangbeen Lee
article en

Abstract

This technical note describes the modernization of the Low-Level Radio Frequency (LLRF) system for the Radio Frequency Quadrupole (RFQ) accelerator at the Korea Atomic Energy Research Institute Heavy Ion Facility (KAHIF). The legacy LLRF system, operating at 25.95 MHz, relied on manual analog controls, which limited operational efficiency and made fault diagnosis difficult due to its opaque circuit configuration. To address these issues, we integrated key hardware components—including a signal generator, a data acquisition (DAQ) module, and an oscilloscope—into the EPICS (Experimental Physics and Industrial Control System) environment. The upgraded system enables precise remote control with a frequency resolution of 40 Hz and an amplitude resolution of 0.04 dBm. Furthermore, real-time monitoring and archiving of RF waveforms and power parameters have been realized, significantly enhancing the operational stability and maintenance efficiency of the RFQ accelerator.

Nuclear Engineering and TechnologyVol. 58(6)
Korea Atomic Energy Research Institute (KR)
Affordable and clean energy
Openalex Percentile: Top 53%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.