A hydro-thermal coupling model for artificial ground freezing considering dynamic phase-change and seepage effects: A case study of the freeze-sealing pipe-roof method

During the freezing period in the artificial ground freezing (AGF) method under seepage conditions, frozen curtain development confronts the coupling effect of phase change and seepage pathways. Traditional models often treat the phase change as static phenomena and set the permeability as a constant value. To capture the dynamic evolution of phase change and their impact on permeability, a temperature-dependent smooth step function is introduced as the phase change function, dynamically linked to water saturation. In this study, a 2D double-pipe model is established to validate the accuracy of the model. Considering phase change, the frozen curtain alters the seepage pathways, preventing forming excessively large and impractical freezing curtain. The results demonstrated that the phase change process under this model can be explicitly embedded within the hydro-thermal coupling framework, dynamically altering permeability and seepage pathways. Subsequently, a case study on Freeze-Sealing Pipe-Roof (FSPR) method was conducted using COMSOL Multiphysics. It was found that seepage induces asymmetric frozen curtain thickness at both upstream and downstream, the thickness of the upstream frozen curtain is generally less than that downstream, with the difference becoming more pronounced as seepage velocity increases. At seepage velocities of 0.2, 0.4 and 0.8 m/d, the required freezing time for the frozen curtain thickness achieving 1.5 m are 45 days, 53 days and 80 days respectively. The critical seepage velocity threshold for achieving 1.5 m within 60 days is 0.7 m/d. These findings highlight the necessity of considering coupled phase-change and seepage effects in simulations to ensure safety.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-02-19
DOI
https://doi.org/10.1016/j.csite.2026.107838
Primary Topic
Climate change and permafrost
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A hydro-thermal coupling model for artificial ground freezing considering dynamic phase-change and seepage effects: A case study of the freeze-sealing pipe-roof method

Songyin Deng, C.X. Lu, S.B. Xue, H. Li
Case Studies in Thermal Engineering
Climate change and permafrost
article

A hydro-thermal coupling model for artificial ground freezing considering dynamic phase-change and seepage effects: A case study of the freeze-sealing pipe-roof method

Songyin Deng, C.X. Lu, S.B. Xue, H. Li
article en

Abstract

During the freezing period in the artificial ground freezing (AGF) method under seepage conditions, frozen curtain development confronts the coupling effect of phase change and seepage pathways. Traditional models often treat the phase change as static phenomena and set the permeability as a constant value. To capture the dynamic evolution of phase change and their impact on permeability, a temperature-dependent smooth step function is introduced as the phase change function, dynamically linked to water saturation. In this study, a 2D double-pipe model is established to validate the accuracy of the model. Considering phase change, the frozen curtain alters the seepage pathways, preventing forming excessively large and impractical freezing curtain. The results demonstrated that the phase change process under this model can be explicitly embedded within the hydro-thermal coupling framework, dynamically altering permeability and seepage pathways. Subsequently, a case study on Freeze-Sealing Pipe-Roof (FSPR) method was conducted using COMSOL Multiphysics. It was found that seepage induces asymmetric frozen curtain thickness at both upstream and downstream, the thickness of the upstream frozen curtain is generally less than that downstream, with the difference becoming more pronounced as seepage velocity increases. At seepage velocities of 0.2, 0.4 and 0.8 m/d, the required freezing time for the frozen curtain thickness achieving 1.5 m are 45 days, 53 days and 80 days respectively. The critical seepage velocity threshold for achieving 1.5 m within 60 days is 0.7 m/d. These findings highlight the necessity of considering coupled phase-change and seepage effects in simulations to ensure safety.

Case Studies in Thermal EngineeringVol. 80
Nanjing Tech University (CN), CCCC Highway Consultants (China) (CN), Zhejiang University (CN)
Openalex Percentile: Top 63%
Climate change and permafrost
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.