Behavior and Predictive Model of Large-Scale Externally Bonded FRP Strips Anchored to Reinforced Concrete Structures

Fiber-reinforced polymer (FRP) anchors are known to enhance load transfer and prevent premature debonding in externally bonded fiber-reinforced polymer (EB-FRP) systems, yet experimental data and design guidelines for single- and multianchored EB-FRP systems under realistic field conditions remain limited. This study investigates the structural performance of anchored EB-FRP joints through a three-round experimental program consisting of 48 large-scale single-lap shear tests on reinforced concrete blocks (up to 1,520 × 450 × 150 mm). The program systematically varied anchor configurations, dowel diameters (7–25 mm), anchor spacing (305–1,215 mm), FRP strip thickness (0.5–6 mm), and concrete compressive strength (19.5–36.1 MPa). A 3D digital image correlation system was used to capture full-field strain and slip profiles, anchor engagement, and interfacial debonding. Anchoring substantially improved both load capacity and slip/deformation response. Sequential engagement was observed in multianchor configurations, and failure modes were governed by the capacity ratio between anchor rupture and strip fracture. An empirical simplified multilinear load–slip model was developed to describe debonding, anchor activation, and subsequent tension-cable action, in which the debonded FRP strips behave like a cable transferring load through the anchors. Model predictions showed strong agreement with test data (R2 = 0.86 for peak load and R2 = 0.81 for ultimate slip). Predictive expressions for anchor capacity and debonding strain were also validated. The results provide a validated framework for the performance-based design of anchored EB-FRP joints and offer guidance on anchorage detailing for structural strengthening applications.

Authors

Institutions

Publication Details

Journal
Journal of Composites for Construction
Published
2026-02-18
DOI
https://doi.org/10.1061/jccof2.cceng-5513
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behavior and Predictive Model of Large-Scale Externally Bonded FRP Strips Anchored to Reinforced Concrete Structures

Lucas Hogan, Enrique del Rey Castillo, Ravi Kanitkar, Aniket D. Borwankar et al.
Journal of Composites for Construction
Structural Behavior of Reinforced Concrete
article

Behavior and Predictive Model of Large-Scale Externally Bonded FRP Strips Anchored to Reinforced Concrete Structures

Lucas Hogan, Enrique del Rey Castillo, Ravi Kanitkar, Aniket D. Borwankar, Tom Allen, Junrui Zhang
article en

Abstract

Fiber-reinforced polymer (FRP) anchors are known to enhance load transfer and prevent premature debonding in externally bonded fiber-reinforced polymer (EB-FRP) systems, yet experimental data and design guidelines for single- and multianchored EB-FRP systems under realistic field conditions remain limited. This study investigates the structural performance of anchored EB-FRP joints through a three-round experimental program consisting of 48 large-scale single-lap shear tests on reinforced concrete blocks (up to 1,520 × 450 × 150 mm). The program systematically varied anchor configurations, dowel diameters (7–25 mm), anchor spacing (305–1,215 mm), FRP strip thickness (0.5–6 mm), and concrete compressive strength (19.5–36.1 MPa). A 3D digital image correlation system was used to capture full-field strain and slip profiles, anchor engagement, and interfacial debonding. Anchoring substantially improved both load capacity and slip/deformation response. Sequential engagement was observed in multianchor configurations, and failure modes were governed by the capacity ratio between anchor rupture and strip fracture. An empirical simplified multilinear load–slip model was developed to describe debonding, anchor activation, and subsequent tension-cable action, in which the debonded FRP strips behave like a cable transferring load through the anchors. Model predictions showed strong agreement with test data (R2 = 0.86 for peak load and R2 = 0.81 for ultimate slip). Predictive expressions for anchor capacity and debonding strain were also validated. The results provide a validated framework for the performance-based design of anchored EB-FRP joints and offer guidance on anchorage detailing for structural strengthening applications.

Journal of Composites for ConstructionVol. 30(3)
University of Auckland (NZ), KLE Academy of Higher Education and Research (IN), Henkel (Germany) (DE)
Sustainable cities and communities
Openalex Percentile: Top 51%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.