A dual-joint compliant architecture for precision control in robotic neuroendoscopy

Neuroendoscopy treats intracranial pathologies through millimeter-scale channels using endoscopes introduced along a straight trajectory from a cranial entry point to the target. The entry point acts as a Remote Center of Motion (RCM), which must remain fixed to follow the surgical plan and avoid damage around the entry point. Existing robotic RCM platforms rely on rigid multi-link structures, increasing complexity and footprint. To mitigate these limitations, we propose a compact dual-joint compliant mechanism for neuroendoscopic manipulation. Building on the Tetra II flexure architecture, we redesigned and optimized the joint for neurosurgical use. The end-effector holder is moved from the central axis to the side to improve visual access, facilitate sterile draping and allow rapid instrument exchange while preserving the RCM constraint. The mechanical design targets directionally uniform stiffness in the working plane while minimizing parasitic RCM displacements. The mechanism uses two identical compliant joints in series, with the connection angle treated as a design variable. For each angle, the response is obtained by analyzing each joint separately in FEM and combining their contributions via rotation matrices. An angular offset of 300° yields near-isotropic stiffness, with a root-mean-square error of 0.90 N/m from an ideal isotropic behavior. A PA12 prototype was tested under 0 . 1 ± 0 . 01 N radial loads. Experimental stiffness differed by ≤ 19% from FEM. The parasitic RCM displacement was 0.032 ± 0.018 mm for a 4.5°shaft rotation, well within the 1 mm neurosurgical tolerance. This dual-joint compliant RCM mechanism offers a practical alternative to conventional rigid-link designs. • Brain endoscopy needs millimetric pivoting to avoid hurting delicate tissue. • Compliant joints keep a stable pivot and remove footprint, friction, wear, backlash. • Dual-compliant joint for robotics neuroendoscopy. • New hybrid methodology for finding stiffness using FEM and rotation matrices.

Authors

Institutions

Publication Details

Journal
Precision Engineering
Published
2026-02-18
DOI
https://doi.org/10.1016/j.precisioneng.2026.02.012
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A dual-joint compliant architecture for precision control in robotic neuroendoscopy

Giovanni Berselli, Federico Mariano, Jovana Jovanova, Leonardo S. Mattos et al.
Precision Engineering
Soft Robotics and Applications
article

A dual-joint compliant architecture for precision control in robotic neuroendoscopy

Giovanni Berselli, Federico Mariano, Jovana Jovanova, Leonardo S. Mattos, Elena De Momi
article en

Abstract

Neuroendoscopy treats intracranial pathologies through millimeter-scale channels using endoscopes introduced along a straight trajectory from a cranial entry point to the target. The entry point acts as a Remote Center of Motion (RCM), which must remain fixed to follow the surgical plan and avoid damage around the entry point. Existing robotic RCM platforms rely on rigid multi-link structures, increasing complexity and footprint. To mitigate these limitations, we propose a compact dual-joint compliant mechanism for neuroendoscopic manipulation. Building on the Tetra II flexure architecture, we redesigned and optimized the joint for neurosurgical use. The end-effector holder is moved from the central axis to the side to improve visual access, facilitate sterile draping and allow rapid instrument exchange while preserving the RCM constraint. The mechanical design targets directionally uniform stiffness in the working plane while minimizing parasitic RCM displacements. The mechanism uses two identical compliant joints in series, with the connection angle treated as a design variable. For each angle, the response is obtained by analyzing each joint separately in FEM and combining their contributions via rotation matrices. An angular offset of 300° yields near-isotropic stiffness, with a root-mean-square error of 0.90 N/m from an ideal isotropic behavior. A PA12 prototype was tested under 0 . 1 ± 0 . 01 N radial loads. Experimental stiffness differed by ≤ 19% from FEM. The parasitic RCM displacement was 0.032 ± 0.018 mm for a 4.5°shaft rotation, well within the 1 mm neurosurgical tolerance. This dual-joint compliant RCM mechanism offers a practical alternative to conventional rigid-link designs. • Brain endoscopy needs millimetric pivoting to avoid hurting delicate tissue. • Compliant joints keep a stable pivot and remove footprint, friction, wear, backlash. • Dual-compliant joint for robotics neuroendoscopy. • New hybrid methodology for finding stiffness using FEM and rotation matrices.

Precision EngineeringVol. 99
Italian Institute of Technology (IT), University of Genoa (IT), Politecnico di Milano (IT), Delft University of Technology (NL)
Sustainable cities and communities
Openalex Percentile: Top 52%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.