Patient-reported outcomes of maxillary palateless monolithic CAD/CAM implant-supported overdentures: A retrospective pilot study

Palateless monolithic CAD/CAM implant-supported overdentures are increasingly used in clinical practice; however, limited clinical data are available regarding patient-reported outcomes associated with this prosthetic design. The purpose of this retrospective pilot study was to evaluate patient-reported outcomes and satisfaction with palateless monolithic CAD/CAM implant-supported overdentures. A questionnaire-based observational study was conducted involving 24 participants rehabilitated with 37 palateless monolithic CAD/CAM implant-supported overdentures retained by LOCATOR attachments. Data were collected through structured telephone interviews using a modified 20-item Visual Analog Scale (VAS) questionnaire, in which each item was scored on a 0–10 scale (total possible score range: 0–200), assessing patient satisfaction related to retention, stability, mastication, comfort, speech, esthetics, psychosocial well-being, and overall acceptance. Descriptive statistics were calculated, and subgroup analyses were performed based on arch configuration, sex, and prior prosthetic experience. The mean follow-up period was 3.1 ± 1.5 years. The overall mean VAS score was 182 ± 18.2, indicating high patient satisfaction. Participants rehabilitated with implant-supported overdentures in both arches reported significantly higher satisfaction than those with a single overdenture opposing natural dentition or fixed prostheses (P = 0.024). Male participants reported significantly higher satisfaction scores than female participants (P = 0.012). No significant difference in satisfaction was observed between participants with or without a history of conventional metal-reinforced overdentures (P > 0.05). Within the limitations of this retrospective pilot study, palateless monolithic CAD/CAM implant-supported overdentures were associated with high patient-reported satisfaction. These findings suggest that this prosthetic design represents a well-accepted treatment option from the patient perspective. Further prospective studies are warranted to confirm these results.

Authors

Institutions

Publication Details

Journal
Digital Dentistry Journal
Published
2026-02-19
DOI
https://doi.org/10.1016/j.ddj.2026.100075
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient-reported outcomes of maxillary palateless monolithic CAD/CAM implant-supported overdentures: A retrospective pilot study

Fahad Alkhtani, Abdulrahman Almalki, Raghdah AlShaibani, Adel Alenazi
Digital Dentistry Journal
Dental Implant Techniques and Outcomes
article

Patient-reported outcomes of maxillary palateless monolithic CAD/CAM implant-supported overdentures: A retrospective pilot study

Fahad Alkhtani, Abdulrahman Almalki, Raghdah AlShaibani, Adel Alenazi
article en

Abstract

Palateless monolithic CAD/CAM implant-supported overdentures are increasingly used in clinical practice; however, limited clinical data are available regarding patient-reported outcomes associated with this prosthetic design. The purpose of this retrospective pilot study was to evaluate patient-reported outcomes and satisfaction with palateless monolithic CAD/CAM implant-supported overdentures. A questionnaire-based observational study was conducted involving 24 participants rehabilitated with 37 palateless monolithic CAD/CAM implant-supported overdentures retained by LOCATOR attachments. Data were collected through structured telephone interviews using a modified 20-item Visual Analog Scale (VAS) questionnaire, in which each item was scored on a 0–10 scale (total possible score range: 0–200), assessing patient satisfaction related to retention, stability, mastication, comfort, speech, esthetics, psychosocial well-being, and overall acceptance. Descriptive statistics were calculated, and subgroup analyses were performed based on arch configuration, sex, and prior prosthetic experience. The mean follow-up period was 3.1 ± 1.5 years. The overall mean VAS score was 182 ± 18.2, indicating high patient satisfaction. Participants rehabilitated with implant-supported overdentures in both arches reported significantly higher satisfaction than those with a single overdenture opposing natural dentition or fixed prostheses (P = 0.024). Male participants reported significantly higher satisfaction scores than female participants (P = 0.012). No significant difference in satisfaction was observed between participants with or without a history of conventional metal-reinforced overdentures (P > 0.05). Within the limitations of this retrospective pilot study, palateless monolithic CAD/CAM implant-supported overdentures were associated with high patient-reported satisfaction. These findings suggest that this prosthetic design represents a well-accepted treatment option from the patient perspective. Further prospective studies are warranted to confirm these results.

Digital Dentistry JournalVol. 3(1)
Princess Nourah bint Abdulrahman University (SA), Prince Sattam Bin Abdulaziz University (SA)
Gender equality
Openalex Percentile: Top 52%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.