A Data-Driven Method for Identifying Similarity in Transmission Sections Considering Energy Storage Regulation Capabilities

To address the challenges of real-time control in power systems with high renewable penetration, identifying historical transmission sections similar to future scenarios enables efficient reuse of mature control strategies. However, existing data-driven identification methods exhibit two primary limitations: they typically rely on static Total Transfer Capacity (TTC), ignoring the rapid regulation capability of Energy Storage Systems (ESS) in alleviating congestion; and they employ fixed weights for similarity measurement, failing to distinguish the varying importance of different features (e.g., critical line flows vs. ordinary voltages). To overcome these issues, this paper proposes a similarity identification method for transmission sections considering ESS regulation capabilities and adaptive feature weights. First, a hierarchical decision model is utilized to screen basic grid features. An optimization model incorporating ESS charge/discharge constraints and emergency power support potential is established to calculate the Dynamic TTC, constructing a multi-scale feature set that reflects the real-time safety margin of the grid. Second, a Dispersion-Weighted Fuzzy C-Means (DW-FCM) clustering algorithm is proposed. By introducing a dispersion-weighting mechanism, the algorithm utilizes data distribution characteristics to automatically learn and assign higher weights to key features with high distinguishability during the iteration process, overcoming the subjectivity of manual weighting. Furthermore, fuzzy validity indices (XB, PC, FS) are introduced to adaptively determine the optimal number of clusters. Finally, case studies on the IEEE 39-bus system verify that the proposed method significantly improves identification accuracy compared to traditional methods and provides more reliable references for dispatching decisions.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-02-17
DOI
https://doi.org/10.3390/electronics15040851
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Data-Driven Method for Identifying Similarity in Transmission Sections Considering Energy Storage Regulation Capabilities

Yifan Su, Leibao Wang, Yangzhi Wang, Wenkai Zhao et al.
Electronics
Power System Optimization and Stability
article

A Data-Driven Method for Identifying Similarity in Transmission Sections Considering Energy Storage Regulation Capabilities

Yifan Su, Leibao Wang, Yangzhi Wang, Wenkai Zhao, Jifeng Liang, Junru Gong
article en

Abstract

To address the challenges of real-time control in power systems with high renewable penetration, identifying historical transmission sections similar to future scenarios enables efficient reuse of mature control strategies. However, existing data-driven identification methods exhibit two primary limitations: they typically rely on static Total Transfer Capacity (TTC), ignoring the rapid regulation capability of Energy Storage Systems (ESS) in alleviating congestion; and they employ fixed weights for similarity measurement, failing to distinguish the varying importance of different features (e.g., critical line flows vs. ordinary voltages). To overcome these issues, this paper proposes a similarity identification method for transmission sections considering ESS regulation capabilities and adaptive feature weights. First, a hierarchical decision model is utilized to screen basic grid features. An optimization model incorporating ESS charge/discharge constraints and emergency power support potential is established to calculate the Dynamic TTC, constructing a multi-scale feature set that reflects the real-time safety margin of the grid. Second, a Dispersion-Weighted Fuzzy C-Means (DW-FCM) clustering algorithm is proposed. By introducing a dispersion-weighting mechanism, the algorithm utilizes data distribution characteristics to automatically learn and assign higher weights to key features with high distinguishability during the iteration process, overcoming the subjectivity of manual weighting. Furthermore, fuzzy validity indices (XB, PC, FS) are introduced to adaptively determine the optimal number of clusters. Finally, case studies on the IEEE 39-bus system verify that the proposed method significantly improves identification accuracy compared to traditional methods and provides more reliable references for dispatching decisions.

ElectronicsVol. 15(4)
Electric Power Research Institute (US), Chongqing University (CN), State Grid Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 52%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.