A High-Sensitive Photothermal-Readout Strategy for Commercial Lateral Flow Immunoassays with an Optical Microfiber Mach–Zehnder Interferometer

Conventional lateral flow immunoassays (LFIAs), which rely on visual interpretation for qualitative analysis, are confronted with limitations such as susceptibility to environmental interference, insufficient sensitivity, and a restricted detection range, thereby hindering its capacity to meet the growing demands of modern point-of-care diagnostics. To address this limitation, the photothermal effect, which converts analyte concentration into quantifiable temperature changes, provides LFIA platforms with enhanced sensitivity and stability. Herein, combining an optical microfiber Mach-Zehnder interferometer (mMZI) with conventional gold nanoparticle (Au NP)-based LFIA strips, a more sensitive photothermal platform (mMZI-LFIA) was engineered for quantitative measurement on LFIA. The proposed mMZI, encapsulated by the high thermo-optical coefficient polymer, exhibits excellent thermal sensitivity, enabling it to capture minute temperature variations due to localized heating generated by the Au NPs via the localized surface plasmon resonance effect. As a proof-of-concept, we employed a sandwich format LFIA for the detection of prostate-specific antigen, used as the model system. The results show high sensitivity with a detection limit (LOD) of 0.347 ng mL<sup>-1</sup>, which was around 11.5 times more sensitive than traditional colorimetric LFIA based on Au NPs. Meanwhile, the mMZI-LFIA broadened the detection range to 0.5-256 ng mL<sup>-1</sup>. Furthermore, to further verify the applicability of the proposed biosensor, quantitative analysis of the competitive Cr<sup>3+</sup> test strips (0.195-50 ng mL<sup>-1</sup>) also achieved LOD (0.235 ng mL<sup>-1</sup>) improvement. In this work, the integration of optical microfibers with commercially available LFIA strips has enabled photothermal quantification in conventional LFIA without requiring additional thermal measurement equipment, significantly enhancing detection sensitivity, accuracy, and reliability, thereby offering a promising new pathway toward the development of portable photothermal LFIA systems.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-02-18
DOI
https://doi.org/10.1021/acs.analchem.5c06666
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Sensitive Photothermal-Readout Strategy for Commercial Lateral Flow Immunoassays with an Optical Microfiber Mach–Zehnder Interferometer

Lili Liang, Bai‐Ou Guan, Canguang Chen, Benfang Xu et al.
Analytical Chemistry
Biosensors and Analytical Detection
article

A High-Sensitive Photothermal-Readout Strategy for Commercial Lateral Flow Immunoassays with an Optical Microfiber Mach–Zehnder Interferometer

Lili Liang, Bai‐Ou Guan, Canguang Chen, Benfang Xu, Li-Peng Sun
article en

Abstract

Conventional lateral flow immunoassays (LFIAs), which rely on visual interpretation for qualitative analysis, are confronted with limitations such as susceptibility to environmental interference, insufficient sensitivity, and a restricted detection range, thereby hindering its capacity to meet the growing demands of modern point-of-care diagnostics. To address this limitation, the photothermal effect, which converts analyte concentration into quantifiable temperature changes, provides LFIA platforms with enhanced sensitivity and stability. Herein, combining an optical microfiber Mach-Zehnder interferometer (mMZI) with conventional gold nanoparticle (Au NP)-based LFIA strips, a more sensitive photothermal platform (mMZI-LFIA) was engineered for quantitative measurement on LFIA. The proposed mMZI, encapsulated by the high thermo-optical coefficient polymer, exhibits excellent thermal sensitivity, enabling it to capture minute temperature variations due to localized heating generated by the Au NPs via the localized surface plasmon resonance effect. As a proof-of-concept, we employed a sandwich format LFIA for the detection of prostate-specific antigen, used as the model system. The results show high sensitivity with a detection limit (LOD) of 0.347 ng mL<sup>-1</sup>, which was around 11.5 times more sensitive than traditional colorimetric LFIA based on Au NPs. Meanwhile, the mMZI-LFIA broadened the detection range to 0.5-256 ng mL<sup>-1</sup>. Furthermore, to further verify the applicability of the proposed biosensor, quantitative analysis of the competitive Cr<sup>3+</sup> test strips (0.195-50 ng mL<sup>-1</sup>) also achieved LOD (0.235 ng mL<sup>-1</sup>) improvement. In this work, the integration of optical microfibers with commercially available LFIA strips has enabled photothermal quantification in conventional LFIA without requiring additional thermal measurement equipment, significantly enhancing detection sensitivity, accuracy, and reliability, thereby offering a promising new pathway toward the development of portable photothermal LFIA systems.

Analytical ChemistryVol. 98(8)
Handan College (CN), Hebei University of Technology (CN), Optics Technology (United States) (US)
Openalex Percentile: Top 52%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.