Angle-compensated non-invasive current measurement of multi-conductor cables via a TMR sensor-array

Real-time current monitoring of currents in smart grid poses significant challenges, particularly within multi-conductor cables where inherent phase imbalance and complex electromagnetic coupling distort the magnetic field patterns, complicating accurate measurement. Conventional non-invasive techniques are often applied to a single conductor, insufficient adaptability to multiple varying conductor arrangements, and require operational interruption for installation. To address these issues, this study designs an angle-compensated non-invasive current measurement method for multi-conductor cables with an annular TMR sensor array. A current inversion model incorporating conductor position and inclination parameters is established. A dual-stage optimization strategy combining Particle Swarm Optimization and the Levenberg–Marquardt Algorithm is proposed to solve the inversion problem efficiently. Experimental results demonstrate that the maximum current error remains below 7% under balanced three-phase conditions. The method also maintains high accuracy in the presence of conductor eccentricity, enabling reliable non-invasive current measurement across diverse multi-conductor configurations.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2026-02-01
DOI
https://doi.org/10.1063/9.0000987
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Angle-compensated non-invasive current measurement of multi-conductor cables via a TMR sensor-array

Changgeng Zhang, Y. X. Li, Fugui Liu, Shuai Zhao et al.
AIP Advances
Magnetic Field Sensors Techniques
article

Angle-compensated non-invasive current measurement of multi-conductor cables via a TMR sensor-array

Changgeng Zhang, Y. X. Li, Fugui Liu, Shuai Zhao, Shuokao Mu
article en

Abstract

Real-time current monitoring of currents in smart grid poses significant challenges, particularly within multi-conductor cables where inherent phase imbalance and complex electromagnetic coupling distort the magnetic field patterns, complicating accurate measurement. Conventional non-invasive techniques are often applied to a single conductor, insufficient adaptability to multiple varying conductor arrangements, and require operational interruption for installation. To address these issues, this study designs an angle-compensated non-invasive current measurement method for multi-conductor cables with an annular TMR sensor array. A current inversion model incorporating conductor position and inclination parameters is established. A dual-stage optimization strategy combining Particle Swarm Optimization and the Levenberg–Marquardt Algorithm is proposed to solve the inversion problem efficiently. Experimental results demonstrate that the maximum current error remains below 7% under balanced three-phase conditions. The method also maintains high accuracy in the presence of conductor eccentricity, enabling reliable non-invasive current measurement across diverse multi-conductor configurations.

AIP AdvancesVol. 16(2)
Hebei University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 52%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.