Electrical and electrochemical pH sensing technologies: comparative mechanisms, performance, and applications

Reliable pH measurement remains central to chemical, biological, and environmental monitoring, yet conventional electrochemical glass electrodes face persistent challenges of fragility, slow response, and limited integrability. This study presents a comparative analysis between a conventional glass-electrode pH meter and a custom-fabricated aluminum interdigitated electrode (Al-IDE) for full-range pH sensing (pH 1–13). The Al-IDE device, fabricated via standard photolithography on thermally oxidized silicon, was evaluated under identical conditions using pure buffer systems. Electrical measurements revealed a distinct U-shaped current response, decreasing from 3107 nA at pH 1 to 1.03 nA near pH 7, before rising to 781 nA at pH 13. This behaviour reflects the amphoteric nature of the Al₂O₃ surface, governed by protonation–deprotonation equilibria that modulate interfacial charge transport. The proposed nonlinear quadratic model achieved strong segmental correlations (R² > 0.89) for both acidic and alkaline regimes. Comparative assessment against the glass electrode yielded a mean absolute deviation of ≈ 0.19 pH units, confirming excellent agreement between the two modalities. While the glass electrode followed a linear Nernstian slope (–58.6 mV pH⁻¹), the Al-IDE offered rapid, reference-free, and mechanically robust operation with repeatability (RSD) ranging up to 3.5%. These findings establish the Al-IDE as a low-cost, CMOS-compatible alternative for portable or embedded pH monitoring and provide foundational insights for hybrid electro-electrical sensing architectures that integrate the precision of electrochemical systems with the real-time responsiveness of electrical transduction.

Authors

Institutions

Publication Details

Journal
Journal of Solid State Electrochemistry
Published
2026-02-18
DOI
https://doi.org/10.1007/s10008-026-06534-y
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical and electrochemical pH sensing technologies: comparative mechanisms, performance, and applications

Assoc. Prof. Uda Hashim, Saroja Rijal, Yuri Pamungkas, M. N. Afnan Uda
Journal of Solid State Electrochemistry
Analytical Chemistry and Sensors
article

Electrical and electrochemical pH sensing technologies: comparative mechanisms, performance, and applications

Assoc. Prof. Uda Hashim, Saroja Rijal, Yuri Pamungkas, M. N. Afnan Uda
article en

Abstract

Reliable pH measurement remains central to chemical, biological, and environmental monitoring, yet conventional electrochemical glass electrodes face persistent challenges of fragility, slow response, and limited integrability. This study presents a comparative analysis between a conventional glass-electrode pH meter and a custom-fabricated aluminum interdigitated electrode (Al-IDE) for full-range pH sensing (pH 1–13). The Al-IDE device, fabricated via standard photolithography on thermally oxidized silicon, was evaluated under identical conditions using pure buffer systems. Electrical measurements revealed a distinct U-shaped current response, decreasing from 3107 nA at pH 1 to 1.03 nA near pH 7, before rising to 781 nA at pH 13. This behaviour reflects the amphoteric nature of the Al₂O₃ surface, governed by protonation–deprotonation equilibria that modulate interfacial charge transport. The proposed nonlinear quadratic model achieved strong segmental correlations (R² > 0.89) for both acidic and alkaline regimes. Comparative assessment against the glass electrode yielded a mean absolute deviation of ≈ 0.19 pH units, confirming excellent agreement between the two modalities. While the glass electrode followed a linear Nernstian slope (–58.6 mV pH⁻¹), the Al-IDE offered rapid, reference-free, and mechanically robust operation with repeatability (RSD) ranging up to 3.5%. These findings establish the Al-IDE as a low-cost, CMOS-compatible alternative for portable or embedded pH monitoring and provide foundational insights for hybrid electro-electrical sensing architectures that integrate the precision of electrochemical systems with the real-time responsiveness of electrical transduction.

Journal of Solid State Electrochemistry
Universiti of Malaysia Sabah (MY), Sepuluh Nopember Institute of Technology (ID), Universiti Malaysia Perlis (MY)
Universiti Malaysia Sabah
Life in Land
Openalex Percentile: Top 54%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.