Evaluation of the Bishop Score in Comparison With Ultrasonographic Markers in Predicting Successful Induction of Labor

Background Induction of labor (IOL) is a common obstetric intervention, yet accurately predicting successful vaginal delivery remains challenging. The Bishop score is widely used to assess cervical readiness, although its predictive performance is limited by subjectivity and variability. Recent studies suggest that ultrasound-based or composite scoring systems may improve the prediction of induction outcomes. The objective of this study was to compare, within a prospective cohort of women undergoing labor induction at ≥34 weeks of gestation, the predictive performance of the Bishop score and a novel ultrasound-based composite induction score for the primary outcome of vaginal delivery. Methods This prospective observational cohort study included 200 women undergoing IOL at ≥34 weeks of gestation for standard obstetric indications. Prior to induction, all participants underwent digital cervical examination for calculation of the Bishop score and standardized ultrasound assessment. The novel induction score integrated sonographic parameters, including cervical length, fetal head characteristics, cervical elastography, and cervical angulation. The primary outcome was vaginal delivery. Receiver operating characteristic curve analysis was used to assess predictive performance. Results The mean maternal age was 30.8 ± 5.4 years, and 56.0% of participants were nulliparous. Vaginal delivery occurred in the majority of cases. The Bishop score demonstrated good predictive ability for vaginal delivery (AUC 0.784, 95% CI 0.686-0.882; p < 0.001). The novel induction score showed significantly higher discriminative performance (AUC 0.891, 95% CI 0.827-0.955; p < 0.001). Clinically relevant cutoffs of the new score provided a more favorable balance between sensitivity and specificity compared with the Bishop score. Conclusions While the Bishop score remains a useful baseline tool, the novel ultrasound-based induction score demonstrated superior predictive accuracy for vaginal delivery. These findings suggest that incorporating objective sonographic parameters into pre-induction assessment may improve risk stratification and support individualized clinical decision-making. External validation is warranted before routine clinical implementation.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-02-18
DOI
https://doi.org/10.7759/cureus.103831
Primary Topic
Maternal and Perinatal Health Interventions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Bishop Score in Comparison With Ultrasonographic Markers in Predicting Successful Induction of Labor

Ekaterini Domali, Antonios Michail, George Daskalakis, Panagiotis Antsaklis
Cureus
Maternal and Perinatal Health Interventions
article

Evaluation of the Bishop Score in Comparison With Ultrasonographic Markers in Predicting Successful Induction of Labor

Ekaterini Domali, Antonios Michail, George Daskalakis, Panagiotis Antsaklis
article en

Abstract

Background Induction of labor (IOL) is a common obstetric intervention, yet accurately predicting successful vaginal delivery remains challenging. The Bishop score is widely used to assess cervical readiness, although its predictive performance is limited by subjectivity and variability. Recent studies suggest that ultrasound-based or composite scoring systems may improve the prediction of induction outcomes. The objective of this study was to compare, within a prospective cohort of women undergoing labor induction at ≥34 weeks of gestation, the predictive performance of the Bishop score and a novel ultrasound-based composite induction score for the primary outcome of vaginal delivery. Methods This prospective observational cohort study included 200 women undergoing IOL at ≥34 weeks of gestation for standard obstetric indications. Prior to induction, all participants underwent digital cervical examination for calculation of the Bishop score and standardized ultrasound assessment. The novel induction score integrated sonographic parameters, including cervical length, fetal head characteristics, cervical elastography, and cervical angulation. The primary outcome was vaginal delivery. Receiver operating characteristic curve analysis was used to assess predictive performance. Results The mean maternal age was 30.8 ± 5.4 years, and 56.0% of participants were nulliparous. Vaginal delivery occurred in the majority of cases. The Bishop score demonstrated good predictive ability for vaginal delivery (AUC 0.784, 95% CI 0.686-0.882; p < 0.001). The novel induction score showed significantly higher discriminative performance (AUC 0.891, 95% CI 0.827-0.955; p < 0.001). Clinically relevant cutoffs of the new score provided a more favorable balance between sensitivity and specificity compared with the Bishop score. Conclusions While the Bishop score remains a useful baseline tool, the novel ultrasound-based induction score demonstrated superior predictive accuracy for vaginal delivery. These findings suggest that incorporating objective sonographic parameters into pre-induction assessment may improve risk stratification and support individualized clinical decision-making. External validation is warranted before routine clinical implementation.

CureusVol. 18(2)
Alexandra Hospital (GR)
Gender equality
Openalex Percentile: Top 48%
Maternal and Perinatal Health Interventions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.