Early Functional Outcomes of Autologous Fibular Strut Graft Augmentation in Open Reduction and Internal Fixation (ORIF) of Proximal Humerus Fractures

Background Displaced proximal humerus fractures in elderly patients are associated with high rates of fixation failure due to poor bone quality and medial column comminution. Augmentation of locking plate fixation with an intramedullary fibular strut autograft has been proposed to enhance medial support and improve outcomes. This study evaluated early radiological and functional outcomes following open reduction and internal fixation (ORIF) using a proximal humerus internal locking system (PHILOS) plate augmented with a fibular strut autograft. Objectives The objectives of this study are to evaluate the early clinical and radiological outcomes of ORIF of displaced proximal humerus fractures using PHILOS plating augmented with an autologous intramedullary fibular strut graft, with emphasis on restoration of medial column support. Methods This prospective observational study included 50 patients with closed displaced proximal humerus fractures treated with ORIF using a PHILOS plate and intramedullary fibular strut autograft. Surgery was performed via a deltopectoral approach. Patients were followed at six weeks, three months, and six months postoperatively. Functional outcomes were assessed using the Constant-Murley score and Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiological union, range of motion, and complications were recorded. Results The mean Constant-Murley score improved from 60.1 at six weeks to 71.9 at three months and 85.3 at six months (p < 0.05). Mean DASH scores decreased from 32.8 to 19.1 and 12.3 at corresponding intervals (p < 0.05). Early radiological union was achieved in all patients (100%). Shoulder range of motion at final follow-up approached near-normal values. One patient (2%) developed a superficial postoperative infection, which resolved with oral antibiotics. No major early complications were observed. No donor-site morbidity was noted. Conclusion Autologous fibular strut graft augmentation during ORIF of displaced proximal humerus fractures is associated with favorable early functional recovery and high early union rates. However, longer follow-up and comparative studies are required to assess long-term complications and durability.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-02-18
DOI
https://doi.org/10.7759/cureus.103867
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Early Functional Outcomes of Autologous Fibular Strut Graft Augmentation in Open Reduction and Internal Fixation (ORIF) of Proximal Humerus Fractures

Mukul Sharma, Davinder Singh, Jaspreet Singh, Harjit Kanwar S Chawla et al.
Cureus
Shoulder Injury and Treatment
article

Early Functional Outcomes of Autologous Fibular Strut Graft Augmentation in Open Reduction and Internal Fixation (ORIF) of Proximal Humerus Fractures

Mukul Sharma, Davinder Singh, Jaspreet Singh, Harjit Kanwar S Chawla, Amandeep S Bakshi
article en

Abstract

Background Displaced proximal humerus fractures in elderly patients are associated with high rates of fixation failure due to poor bone quality and medial column comminution. Augmentation of locking plate fixation with an intramedullary fibular strut autograft has been proposed to enhance medial support and improve outcomes. This study evaluated early radiological and functional outcomes following open reduction and internal fixation (ORIF) using a proximal humerus internal locking system (PHILOS) plate augmented with a fibular strut autograft. Objectives The objectives of this study are to evaluate the early clinical and radiological outcomes of ORIF of displaced proximal humerus fractures using PHILOS plating augmented with an autologous intramedullary fibular strut graft, with emphasis on restoration of medial column support. Methods This prospective observational study included 50 patients with closed displaced proximal humerus fractures treated with ORIF using a PHILOS plate and intramedullary fibular strut autograft. Surgery was performed via a deltopectoral approach. Patients were followed at six weeks, three months, and six months postoperatively. Functional outcomes were assessed using the Constant-Murley score and Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiological union, range of motion, and complications were recorded. Results The mean Constant-Murley score improved from 60.1 at six weeks to 71.9 at three months and 85.3 at six months (p < 0.05). Mean DASH scores decreased from 32.8 to 19.1 and 12.3 at corresponding intervals (p < 0.05). Early radiological union was achieved in all patients (100%). Shoulder range of motion at final follow-up approached near-normal values. One patient (2%) developed a superficial postoperative infection, which resolved with oral antibiotics. No major early complications were observed. No donor-site morbidity was noted. Conclusion Autologous fibular strut graft augmentation during ORIF of displaced proximal humerus fractures is associated with favorable early functional recovery and high early union rates. However, longer follow-up and comparative studies are required to assess long-term complications and durability.

CureusVol. 18(2)
Government Medical College (IN)
No poverty
Openalex Percentile: Top 52%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.