Implant Navigation During TMJ Reconstruction: A Proof-of-Concept Study

<b>Background/Objectives</b>: One key objective in temporomandibular joint replacement is to precisely position the implant according to the virtual surgical plan, utilizing drilling and osteotomy guides for accuracy. However, implementing this process can be challenging, as-even though the drilling and osteotomy guides should only fit in one position-there often are still multiple potential positions for both guides and implants on smooth bony surfaces. Even minor deviations in the implant's placement can affect wear, influence biomechanical behavior, and lead to adverse outcomes. Intraoperative navigation has emerged to verify the alignment of implants with the preoperatively planned ideal position. While the use of navigation systems in TMJ surgery is well documented for certain procedures, its application in TMJ replacement cases has been limited. <b>Methods</b>: In this study, two methods to improve the accuracy of TMJ replacement are introduced: a new marker-based navigation workflow and the use of orientation screws in two patients. <b>Results</b>: Unlike conventional navigation methods, the marker-based system provides a more intuitive method for assessing the 3D orientation of the TMJ implant concerning the planned position, enhancing surgical accuracy. The addition of a guiding screw provides a reference point to enhance the accuracy of guide placement. <b>Conclusions</b>: The accurate placement of the prosthesis largely relies on the precise positioning of the guides. Even slight inaccuracies in the position of the TMJ prosthesis, resulting from suboptimal guide placement, can lead to significant negative clinical outcomes. Marker-based navigation and the use of guiding screws may potentially improve the precision of TMJ replacement procedures.

Authors

Institutions

Publication Details

Journal
Journal of Personalized Medicine
Published
2026-02-18
DOI
https://doi.org/10.3390/jpm16020122
Primary Topic
Temporomandibular Joint Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implant Navigation During TMJ Reconstruction: A Proof-of-Concept Study

Lauren C. M. Bulthuis, Petra Zuurbier, Jan de Lange, Ruud Schreurs et al.
Journal of Personalized Medicine
Temporomandibular Joint Disorders
article

Implant Navigation During TMJ Reconstruction: A Proof-of-Concept Study

Lauren C. M. Bulthuis, Petra Zuurbier, Jan de Lange, Ruud Schreurs, Jean-Pierre T. F. Ho, Michail Koutris
article en

Abstract

<b>Background/Objectives</b>: One key objective in temporomandibular joint replacement is to precisely position the implant according to the virtual surgical plan, utilizing drilling and osteotomy guides for accuracy. However, implementing this process can be challenging, as-even though the drilling and osteotomy guides should only fit in one position-there often are still multiple potential positions for both guides and implants on smooth bony surfaces. Even minor deviations in the implant's placement can affect wear, influence biomechanical behavior, and lead to adverse outcomes. Intraoperative navigation has emerged to verify the alignment of implants with the preoperatively planned ideal position. While the use of navigation systems in TMJ surgery is well documented for certain procedures, its application in TMJ replacement cases has been limited. <b>Methods</b>: In this study, two methods to improve the accuracy of TMJ replacement are introduced: a new marker-based navigation workflow and the use of orientation screws in two patients. <b>Results</b>: Unlike conventional navigation methods, the marker-based system provides a more intuitive method for assessing the 3D orientation of the TMJ implant concerning the planned position, enhancing surgical accuracy. The addition of a guiding screw provides a reference point to enhance the accuracy of guide placement. <b>Conclusions</b>: The accurate placement of the prosthesis largely relies on the precise positioning of the guides. Even slight inaccuracies in the position of the TMJ prosthesis, resulting from suboptimal guide placement, can lead to significant negative clinical outcomes. Marker-based navigation and the use of guiding screws may potentially improve the precision of TMJ replacement procedures.

Journal of Personalized MedicineVol. 16(2)
Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Academic Center for Dentistry Amsterdam (NL), Radboud Institute for Molecular Life Sciences (NL), Amsterdam University Medical Centers (NL), Vrije Universiteit Amsterdam (NL), University of Amsterdam (NL)
Openalex Percentile: Top 52%
Temporomandibular Joint Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.