Assessment of Xsens Motion Trackers’ Accuracy to Measure Induced Vibrations During Endurance Running

<b>Background:</b> Research on vibrations induced by running has gained significant attention due to its implications for athletes' performance, injury prevention, and overall well-being. Distance running exposes the body to repetitive impulsive forces, causing significant vibrations to travel through physiological systems and biomechanical structures. These vibrations increase fatigue and the risk of injury. Although it has gained importance, research on induced vibration during running and wearable equipment for monitoring is scarce. This study aims to evaluate the performance of a measurement system for monitoring the acceleration levels of induced vibrations during long-distance running, exploring the capability of non-invasive wearable devices to characterise vibration transmissibility and exposure. Moreover, a preliminary quantitative assessment of induced vibration levels for an indoor testing scenario is given. <b>Methods:</b> Metrological characterisation of Xsens Motion Trackers Awinda (MTw), off-the-shelf inertial magnetic motion trackers, was performed by measuring the sensors' frequency bandwidth in a controlled environment, providing logarithmic sweep sine excitations at different levels (2 <i>g</i>, 5 <i>g</i>, 7 <i>g</i>, where <i>g</i> is meant to be the gravitational acceleration). A testing protocol for indoor testing was derived from the literature, allowing characterisation of the sensors' behaviour in terms of vibration transmissibility and exposure detection in the intended application. Time domain and frequency domain analyses were conducted by following the ISO 2631 standard guideline for vibration exposure assessment, and measurement uncertainty was defined, either for the dynamic correction of the sensors' frequency behaviour or for the computed time and frequency domain metrics. In this framework, a treadmill-based test was conducted. The aim was to evaluate the Xsens sensors' performance in measuring vibration dose exposure and transmissibility. Three MTws were placed on the subject's right tibia, back, and forehead using elastic bands. A 25-year-old female amateur runner completed a series of tests consisting of walking for 1 min at 3.5 km/h (instrumentation setup), followed by running at two speeds (8 km/h and 11 km/h) for 2-4 min per trial, with 5 min rest periods between tests. <b>Conclusions:</b> The tested measurement system showed promising results due to its capability to assess vibration exposure during sports activities, but dynamic correction was found to be mandatory for accurate vibration level assessment. The main outcome of this study is a method for characterising the accelerometers embedded in the proposed devices, along with an analysis strategy for future testing campaigns. Thanks to the portability of IMUs (inertial measurement units), this approach enables the evaluation of induced vibrations during in-field running measurements.

Authors

Institutions

Publication Details

Journal
Journal of Functional Morphology and Kinesiology
Published
2026-02-18
DOI
https://doi.org/10.3390/jfmk11010082
Primary Topic
Effects of Vibration on Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Xsens Motion Trackers’ Accuracy to Measure Induced Vibrations During Endurance Running

Diego Scaccabarozzi, Andrea Appiani, Chiara Martina
Journal of Functional Morphology and Kinesiology
Effects of Vibration on Health
article

Assessment of Xsens Motion Trackers’ Accuracy to Measure Induced Vibrations During Endurance Running

Diego Scaccabarozzi, Andrea Appiani, Chiara Martina
article en

Abstract

<b>Background:</b> Research on vibrations induced by running has gained significant attention due to its implications for athletes' performance, injury prevention, and overall well-being. Distance running exposes the body to repetitive impulsive forces, causing significant vibrations to travel through physiological systems and biomechanical structures. These vibrations increase fatigue and the risk of injury. Although it has gained importance, research on induced vibration during running and wearable equipment for monitoring is scarce. This study aims to evaluate the performance of a measurement system for monitoring the acceleration levels of induced vibrations during long-distance running, exploring the capability of non-invasive wearable devices to characterise vibration transmissibility and exposure. Moreover, a preliminary quantitative assessment of induced vibration levels for an indoor testing scenario is given. <b>Methods:</b> Metrological characterisation of Xsens Motion Trackers Awinda (MTw), off-the-shelf inertial magnetic motion trackers, was performed by measuring the sensors' frequency bandwidth in a controlled environment, providing logarithmic sweep sine excitations at different levels (2 <i>g</i>, 5 <i>g</i>, 7 <i>g</i>, where <i>g</i> is meant to be the gravitational acceleration). A testing protocol for indoor testing was derived from the literature, allowing characterisation of the sensors' behaviour in terms of vibration transmissibility and exposure detection in the intended application. Time domain and frequency domain analyses were conducted by following the ISO 2631 standard guideline for vibration exposure assessment, and measurement uncertainty was defined, either for the dynamic correction of the sensors' frequency behaviour or for the computed time and frequency domain metrics. In this framework, a treadmill-based test was conducted. The aim was to evaluate the Xsens sensors' performance in measuring vibration dose exposure and transmissibility. Three MTws were placed on the subject's right tibia, back, and forehead using elastic bands. A 25-year-old female amateur runner completed a series of tests consisting of walking for 1 min at 3.5 km/h (instrumentation setup), followed by running at two speeds (8 km/h and 11 km/h) for 2-4 min per trial, with 5 min rest periods between tests. <b>Conclusions:</b> The tested measurement system showed promising results due to its capability to assess vibration exposure during sports activities, but dynamic correction was found to be mandatory for accurate vibration level assessment. The main outcome of this study is a method for characterising the accelerometers embedded in the proposed devices, along with an analysis strategy for future testing campaigns. Thanks to the portability of IMUs (inertial measurement units), this approach enables the evaluation of induced vibrations during in-field running measurements.

Journal of Functional Morphology and KinesiologyVol. 11(1)
Politecnico di Milano (IT)
Good health and well-being
Openalex Percentile: Top 53%
Effects of Vibration on Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.