Gaseous reference standard for breath analysis

An increasing amount of research is going into detecting volatile organic compounds (VOCs) in exhaled breath to detect diseases and personalize treatment for patients: recently, these analytes has risen as potential biomarkers. The present work aims to examine different multi-component gas mixtures suitable for breath gas analysis. In addition, also the stability of these mixtures was investigated. The number of components tested were 31, divided in two gas mixtures A and B. These components are aldehydes, acetate compounds, aromatics compounds: the lists are available in the article. Gas components of mixture A and B were prepared in different concentration from 1 µmol/mol to 10 nmol/mol. All the mixtures were analytically verified and the expected analytical relative uncertainty is 10-15% for 10 nmol/mol mixture. The stability check is also performed after 1 year and 2 years. The mixtures demonstrated good stability, and tests are still on going.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-02-17
DOI
https://doi.org/10.1051/epjconf/202635202002/pdf
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gaseous reference standard for breath analysis

G. Bissolotti, Laura Gagni
Springer Link (Chiba Institute of Technology)
Advanced Chemical Sensor Technologies
article

Gaseous reference standard for breath analysis

G. Bissolotti, Laura Gagni
article en

Abstract

An increasing amount of research is going into detecting volatile organic compounds (VOCs) in exhaled breath to detect diseases and personalize treatment for patients: recently, these analytes has risen as potential biomarkers. The present work aims to examine different multi-component gas mixtures suitable for breath gas analysis. In addition, also the stability of these mixtures was investigated. The number of components tested were 31, divided in two gas mixtures A and B. These components are aldehydes, acetate compounds, aromatics compounds: the lists are available in the article. Gas components of mixture A and B were prepared in different concentration from 1 µmol/mol to 10 nmol/mol. All the mixtures were analytically verified and the expected analytical relative uncertainty is 10-15% for 10 nmol/mol mixture. The stability check is also performed after 1 year and 2 years. The mixtures demonstrated good stability, and tests are still on going.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 52%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.