Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported Restorations

<b>Background:</b> Digital technologies, particularly CAD/CAM workflows, have transformed implant prosthodontics by improving the accuracy and efficiency of impression procedures, facilitating clinician-laboratory communication, and supporting the preservation of peri-implant tissues. <b>Objective:</b> To compare the three-dimensional accuracy (trueness) and passive fit of five conventional and digital impression techniques for fixed prostheses supported by two implants. <b>Methods:</b> An in vitro experimental study was conducted using a partially edentulous maxillary model with two implants supporting a three-unit zirconia bridge. Five impression workflows were evaluated: conventional techniques (open-tray and closed-tray, splinted and non-splinted) and digital impressions using plastic and titanium scan bodies. Three-dimensional accuracy was assessed by digital superimposition analysis, and passive fit was evaluated by marginal gap measurements using digital microscopy and ImageJ (version 1.54r) software. Statistical analyses were performed using exploratory ANOVA with Welch's correction and Games-Howell post hoc tests (<i>p</i> < 0.05), complemented by effect size analysis. <b>Results:</b> Three-dimensional superimposition analysis revealed that digital impression workflows and the splinted conventional open-tray technique exhibited the highest trueness, with minimal spatial deviations relative to the reference model, together with the lowest marginal gap values (<1 µm). The non-splinted open-tray technique presented higher discrepancies (7.37 ± 0.94 µm), although all techniques remained within clinically acceptable tolerance ranges (60-150 µm). <b>Conclusions:</b> Under controlled in vitro conditions, both digital impression techniques and conventional splinted protocols achieve high three-dimensional accuracy and clinically acceptable passive fit for multi-implant-supported fixed prostheses. Digital workflows represent a predictable and efficient alternative, while conventional splinted impressions remain a reliable option depending on clinical and technological considerations.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2026-02-18
DOI
https://doi.org/10.3390/dj14020120
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported Restorations

Cristian Abad‐Coronel, Paulina Aliaga, Diana Margarita Díaz Estrada, Nancy Mena Córdova et al.
Dentistry Journal
Dental Implant Techniques and Outcomes
article

Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported Restorations

Cristian Abad‐Coronel, Paulina Aliaga, Diana Margarita Díaz Estrada, Nancy Mena Córdova, David Ruiz, Miguel Ángel Quelal
article en

Abstract

<b>Background:</b> Digital technologies, particularly CAD/CAM workflows, have transformed implant prosthodontics by improving the accuracy and efficiency of impression procedures, facilitating clinician-laboratory communication, and supporting the preservation of peri-implant tissues. <b>Objective:</b> To compare the three-dimensional accuracy (trueness) and passive fit of five conventional and digital impression techniques for fixed prostheses supported by two implants. <b>Methods:</b> An in vitro experimental study was conducted using a partially edentulous maxillary model with two implants supporting a three-unit zirconia bridge. Five impression workflows were evaluated: conventional techniques (open-tray and closed-tray, splinted and non-splinted) and digital impressions using plastic and titanium scan bodies. Three-dimensional accuracy was assessed by digital superimposition analysis, and passive fit was evaluated by marginal gap measurements using digital microscopy and ImageJ (version 1.54r) software. Statistical analyses were performed using exploratory ANOVA with Welch's correction and Games-Howell post hoc tests (<i>p</i> < 0.05), complemented by effect size analysis. <b>Results:</b> Three-dimensional superimposition analysis revealed that digital impression workflows and the splinted conventional open-tray technique exhibited the highest trueness, with minimal spatial deviations relative to the reference model, together with the lowest marginal gap values (<1 µm). The non-splinted open-tray technique presented higher discrepancies (7.37 ± 0.94 µm), although all techniques remained within clinically acceptable tolerance ranges (60-150 µm). <b>Conclusions:</b> Under controlled in vitro conditions, both digital impression techniques and conventional splinted protocols achieve high three-dimensional accuracy and clinically acceptable passive fit for multi-implant-supported fixed prostheses. Digital workflows represent a predictable and efficient alternative, while conventional splinted impressions remain a reliable option depending on clinical and technological considerations.

Dentistry JournalVol. 14(2)
University of Cuenca (EC), Universidad San Francisco de Quito (EC)
Sustainable cities and communities
Openalex Percentile: Top 53%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.