Experimental assessment of a novel photovoltaic heat pump design with dual condenser

• Novel heat pump with two condensers and improved control was experimentally tested. • Design shifts DHW production to solar hours, boosting self-consumption. • COP improved from 3.46 to 7.59 with dual condenser and PV panels. • Solar contribution rose sharply from 9.9 % to 55.5 % with new configuration. • Results show strong potential for PV–HP integration to cut CO 2 emissions. The pursuit of near-zero energy buildings demands highly efficient domestic hot water (DHW) systems. Fossil fuels are no longer viable, and electrification alone is insufficient without high efficiency. Heat pumps (HPs) offer an optimal solution and can be considered renewable when their coefficient of performance (COP) exceeds 2.5. Although HP technology has advanced considerably, efficiency remains variable depending on operating conditions. Integrating photovoltaic (PV) systems can enhance performance, yet mismatches between HP operation and PV generation limit self-consumption. This study presents a novel HP configuration designed to shift DHW production to central daylight hours, maximizing PV utilization and system efficiency. The proposed design incorporates two condensers—placed at the top and bottom of the water tank—controlled to optimize thermal stratification and energy performance. Experimental testing compared three setups: conventional HP, HP with PV panels, and the new two-condenser HP with PV panels. Results show the COP increased from 3.55 to 4.05 with PV integration and reached 8.34 with the dual-condenser configuration at 18 °C ambient temperature. Moreover, the redesigned system shifted energy use toward PV production periods, raising solar contribution from 9.9 % to 55.5 %. The proposed configuration demonstrates significant potential for efficient, renewable DHW production.

Authors

Institutions

Publication Details

Journal
Solar Energy
Published
2026-02-18
DOI
https://doi.org/10.1016/j.solener.2026.114431
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental assessment of a novel photovoltaic heat pump design with dual condenser

F. Aguilar, L. Nebot-Andrés, P. Vicente
Solar Energy
Geothermal Energy Systems and Applications
article

Experimental assessment of a novel photovoltaic heat pump design with dual condenser

F. Aguilar, L. Nebot-Andrés, P. Vicente
article en

Abstract

• Novel heat pump with two condensers and improved control was experimentally tested. • Design shifts DHW production to solar hours, boosting self-consumption. • COP improved from 3.46 to 7.59 with dual condenser and PV panels. • Solar contribution rose sharply from 9.9 % to 55.5 % with new configuration. • Results show strong potential for PV–HP integration to cut CO 2 emissions. The pursuit of near-zero energy buildings demands highly efficient domestic hot water (DHW) systems. Fossil fuels are no longer viable, and electrification alone is insufficient without high efficiency. Heat pumps (HPs) offer an optimal solution and can be considered renewable when their coefficient of performance (COP) exceeds 2.5. Although HP technology has advanced considerably, efficiency remains variable depending on operating conditions. Integrating photovoltaic (PV) systems can enhance performance, yet mismatches between HP operation and PV generation limit self-consumption. This study presents a novel HP configuration designed to shift DHW production to central daylight hours, maximizing PV utilization and system efficiency. The proposed design incorporates two condensers—placed at the top and bottom of the water tank—controlled to optimize thermal stratification and energy performance. Experimental testing compared three setups: conventional HP, HP with PV panels, and the new two-condenser HP with PV panels. Results show the COP increased from 3.55 to 4.05 with PV integration and reached 8.34 with the dual-condenser configuration at 18 °C ambient temperature. Moreover, the redesigned system shifted energy use toward PV production periods, raising solar contribution from 9.9 % to 55.5 %. The proposed configuration demonstrates significant potential for efficient, renewable DHW production.

Solar EnergyVol. 309
Universitat de Miguel Hernández d'Elx (ES)
Affordable and clean energy
Openalex Percentile: Top 54%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.