Failure mechanisms in silicon and silicon-graphite electrodes cycled in ionic liquid electrolyte

Combining silicon and graphite in electrode materials leverages the high energy density of silicon while using graphite to mitigate the significant volumetric expansion of silicon based electrodes during cycling. Such combination will impact the formation and evolution of the solid electrolyte interphase (SEI). In this study, we compare silicon (Si) and silicon/graphite blend Si/Gr (50:50) electrodes and investigated their electrochemical performance in a highly concentrated triethyl(methyl)phosphonium bis(fluorosulfonyl)imide (P1222FSI) ionic liquid electrolyte in both half-cells and full-cells. Through a combination of transmission electron microscopy (STEM-EDX), X-ray photoelectron spectroscopy (XPS), and magic angle spinning nuclear magnetic resonance (MAS-NMR), we monitored the evolution of the SEI and silicon particles morphology. Although displaying similar capacity fading profile, failure mechanisms for Si and Si/Gr electrodes cycled in full-cell configuration are completely different. For Si/Gr blend full-cells, nano-porosification of silicon particles occurs, leading to SEI accumulation and the capacity fade is largely attributed to the loss of cyclable lithium. Contrarily, the absence of nano-porosification and an extremely stable and blocking SEI characterize Si electrodes in full-cell. This study provides new insights into how SEI evolution and silicon morphology impact the electrochemical performance of Si and Si/Gr blend electrodes across different cell configurations in non-carbonated electrolytes. • SEI evolution for Si and Si/Gr electrodes in ionic liquid electrolyte. • Different failure mechanisms in half- and full-cells. • Stable SEI for Si electrode in highly concentrated ionic liquid electrolyte.

Authors

Institutions

Publication Details

Journal
Journal of Power Sources
Published
2026-02-18
DOI
https://doi.org/10.1016/j.jpowsour.2026.239649
Primary Topic
Advancements in Battery Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Failure mechanisms in silicon and silicon-graphite electrodes cycled in ionic liquid electrolyte

Jean Le Bideau, Boluwatife Igbaroola, Nicolas Dupré, N. Gautier et al.
Journal of Power Sources
Advancements in Battery Materials
article

Failure mechanisms in silicon and silicon-graphite electrodes cycled in ionic liquid electrolyte

Jean Le Bideau, Boluwatife Igbaroola, Nicolas Dupré, N. Gautier, Jonathan Hamon, Patrick C. Howlett, Bernard Lestriez
article en

Abstract

Combining silicon and graphite in electrode materials leverages the high energy density of silicon while using graphite to mitigate the significant volumetric expansion of silicon based electrodes during cycling. Such combination will impact the formation and evolution of the solid electrolyte interphase (SEI). In this study, we compare silicon (Si) and silicon/graphite blend Si/Gr (50:50) electrodes and investigated their electrochemical performance in a highly concentrated triethyl(methyl)phosphonium bis(fluorosulfonyl)imide (P1222FSI) ionic liquid electrolyte in both half-cells and full-cells. Through a combination of transmission electron microscopy (STEM-EDX), X-ray photoelectron spectroscopy (XPS), and magic angle spinning nuclear magnetic resonance (MAS-NMR), we monitored the evolution of the SEI and silicon particles morphology. Although displaying similar capacity fading profile, failure mechanisms for Si and Si/Gr electrodes cycled in full-cell configuration are completely different. For Si/Gr blend full-cells, nano-porosification of silicon particles occurs, leading to SEI accumulation and the capacity fade is largely attributed to the loss of cyclable lithium. Contrarily, the absence of nano-porosification and an extremely stable and blocking SEI characterize Si electrodes in full-cell. This study provides new insights into how SEI evolution and silicon morphology impact the electrochemical performance of Si and Si/Gr blend electrodes across different cell configurations in non-carbonated electrolytes. • SEI evolution for Si and Si/Gr electrodes in ionic liquid electrolyte. • Different failure mechanisms in half- and full-cells. • Stable SEI for Si electrode in highly concentrated ionic liquid electrolyte.

Journal of Power SourcesVol. 672
Centre National de la Recherche Scientifique (FR), Deakin University (AU), Institut des Matériaux Jean Rouxel (FR)
Affordable and clean energy
Openalex Percentile: Top 52%
Advancements in Battery Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.