Telescoping rodding with adjunctive external fixation or threaded wires in osteogenesis imperfecta: evaluation of outcomes

The use of locking plates with intramedullary rodding in children with osteogenesis imperfecta reduces rotational and longitudinal instability. However, adjunctive locking plates do not allow early weight-bearing. We explored the outcomes of intramedullary rodding combined with external fixation or titanium threaded wires (ThW). The study included osteogenesis imperfecta children who underwent surgery with intramedullary telescopic rods and adjunctive fixation with external fixation or ThW. The timing of and reason for implant failure were primary outcome variables. Our cohort consisted of 62 limb segments in 24 patients. The mean external fixation duration was 40.2 days (femur) and 44.3 days (tibia). Patients with external fixation were verticalized with weight-bearing during the first postoperative week. Eleven rod revisions were performed (mean follow-up 50.9 months). We found no fractures after external fixation removal, no rotational displacement, or cortical gaps. We did not observe complications related to ThW. The use of external fixation as an adjunct to telescopic rodding appears feasible and reproducible method for managing deformities in osteogenesis imperfecta children. Use of titanium telescopic rods is associated with a similar revision rate compared to the most commonly used rods. Intramedullary rodding with adjunctive external fixation enables early weight-bearing. Rotational and longitudinal stability ensured by the combined fixation eliminates the risk of secondary rotational displacement, cortical gap, and nonunion. The combination with threaded wires did not show the inconveniences of locking plates used as an adjunct. Results should be interpreted as feasibility data from a retrospective case series.

Authors

Institutions

Publication Details

Journal
Journal of Pediatric Orthopaedics B
Published
2026-02-18
DOI
https://doi.org/10.1097/bpb.0000000000001338
Primary Topic
Connective tissue disorders research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Telescoping rodding with adjunctive external fixation or threaded wires in osteogenesis imperfecta: evaluation of outcomes

D. A. Popkov, Eduard Mingazov, Arnold Popkov, Nikita Gvozdev et al.
Journal of Pediatric Orthopaedics B
Connective tissue disorders research
article

Telescoping rodding with adjunctive external fixation or threaded wires in osteogenesis imperfecta: evaluation of outcomes

D. A. Popkov, Eduard Mingazov, Arnold Popkov, Nikita Gvozdev, David Podeszwa
article en

Abstract

The use of locking plates with intramedullary rodding in children with osteogenesis imperfecta reduces rotational and longitudinal instability. However, adjunctive locking plates do not allow early weight-bearing. We explored the outcomes of intramedullary rodding combined with external fixation or titanium threaded wires (ThW). The study included osteogenesis imperfecta children who underwent surgery with intramedullary telescopic rods and adjunctive fixation with external fixation or ThW. The timing of and reason for implant failure were primary outcome variables. Our cohort consisted of 62 limb segments in 24 patients. The mean external fixation duration was 40.2 days (femur) and 44.3 days (tibia). Patients with external fixation were verticalized with weight-bearing during the first postoperative week. Eleven rod revisions were performed (mean follow-up 50.9 months). We found no fractures after external fixation removal, no rotational displacement, or cortical gaps. We did not observe complications related to ThW. The use of external fixation as an adjunct to telescopic rodding appears feasible and reproducible method for managing deformities in osteogenesis imperfecta children. Use of titanium telescopic rods is associated with a similar revision rate compared to the most commonly used rods. Intramedullary rodding with adjunctive external fixation enables early weight-bearing. Rotational and longitudinal stability ensured by the combined fixation eliminates the risk of secondary rotational displacement, cortical gap, and nonunion. The combination with threaded wires did not show the inconveniences of locking plates used as an adjunct. Results should be interpreted as feasibility data from a retrospective case series.

Journal of Pediatric Orthopaedics B
Russian Ilizarov Scientific Center for Restorative Traumatology and Orthopaedics (RU), Texas Scottish Rite Hospital for Children (US)
Openalex Percentile: Top 49%
Connective tissue disorders research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Telescoping rodding with adjunctive external fixation or threaded wires in osteogenesis imperfecta: evaluation of outcomes — D. A. Popkov, Eduard Mingazov, et al. · Journal of Pediatric Orthopaedics B (2026) | TGRS Research Map | TGRS