Performance investigation of a quasi-saturated compression high-temperature heat pump system with water-injection

Water vapor high-temperature heat pump (HTHP) combines the environmental friendliness of natural water and the energy-saving of heat pump, which fully exerts the performance advantages of water working fluid in the field of HTHPs. Injecting the atomized water or low-enthalpy gas-liquid mixture into the compression chamber can not only effectively reduce the exhaust temperature and superheat at the end of compression, but also contributes to the overall performance improvement of the system. The theoretical analysis and experimental investigation of the effect of water-injection cooling on the system performance were carried out. It was concluded that the increase in number of water-injection is beneficial to the system performance. However, when the number of water-injection exceed 5, the improvement of the system performance will be very slow. When the number of water-injection reached 20, COP increased by 12.05-19.27% compared with no water-injection. The experimental results also indicate that water-injection can be used to realize the quasi-saturated compression process, which will help decrease the discharge superheat and ensure the long-time safe operation of the water vapor HTHP. When the water-injection flow rate ensures the quasi-saturated compression process of the system, then increasing the injected water will not have a significant impact on the system performance. Under the conditions of 80 °C evaporation temperature and 125 °C condensation temperature, when the system operating condition is stable, and the water-injection flow rate is gradually reduced from 90L∙h −1 , the system energy consumption is 49 kW, the heating capacity is 172 kW, and the COP is 3.5. • The increase in number of water injection is beneficial to the water vapor HTHP performance. • Water-injection can be used to realize the quasi-saturated compression process of water vapor. • Under the conditions of 80 °C evaporation and 125 °C condensation, the COP is 3.5.

Authors

Institutions

Publication Details

Journal
Energy
Published
2026-02-18
DOI
https://doi.org/10.1016/j.energy.2026.140456
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance investigation of a quasi-saturated compression high-temperature heat pump system with water-injection

Shengong Mei, W Chen, Fudong Xin, Dan Wu et al.
Energy
Refrigeration and Air Conditioning Technologies
article

Performance investigation of a quasi-saturated compression high-temperature heat pump system with water-injection

Shengong Mei, W Chen, Fudong Xin, Dan Wu, Chaohe Fang, Bo Xiong, Bin Hu, R.Z. Wang, Qinghong Zhao
article en

Abstract

Water vapor high-temperature heat pump (HTHP) combines the environmental friendliness of natural water and the energy-saving of heat pump, which fully exerts the performance advantages of water working fluid in the field of HTHPs. Injecting the atomized water or low-enthalpy gas-liquid mixture into the compression chamber can not only effectively reduce the exhaust temperature and superheat at the end of compression, but also contributes to the overall performance improvement of the system. The theoretical analysis and experimental investigation of the effect of water-injection cooling on the system performance were carried out. It was concluded that the increase in number of water-injection is beneficial to the system performance. However, when the number of water-injection exceed 5, the improvement of the system performance will be very slow. When the number of water-injection reached 20, COP increased by 12.05-19.27% compared with no water-injection. The experimental results also indicate that water-injection can be used to realize the quasi-saturated compression process, which will help decrease the discharge superheat and ensure the long-time safe operation of the water vapor HTHP. When the water-injection flow rate ensures the quasi-saturated compression process of the system, then increasing the injected water will not have a significant impact on the system performance. Under the conditions of 80 °C evaporation temperature and 125 °C condensation temperature, when the system operating condition is stable, and the water-injection flow rate is gradually reduced from 90L∙h −1 , the system energy consumption is 49 kW, the heating capacity is 172 kW, and the COP is 3.5. • The increase in number of water injection is beneficial to the water vapor HTHP performance. • Water-injection can be used to realize the quasi-saturated compression process of water vapor. • Under the conditions of 80 °C evaporation and 125 °C condensation, the COP is 3.5.

EnergyVol. 347
Shanghai Jiao Tong University (CN), Energy Research Institute (CN), Research Institute of Petroleum Exploration and Development (CN)
Affordable and clean energy
Openalex Percentile: Top 53%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.