Process of phosphate removal in Fe0/H2O systems: A novel kinetic model considering iron corrosion at neutral pH

• A kinetic model considering dynamics of Fe 0 corrosion is developed for Fe 0 /H 2 O systems • The model outperforms conventional kinetic models in describing phosphate removal • Iron corrosion is the rate-limiting step for phosphate removal in Fe 0 /H 2 O systems at neutral pH • Fe 0 -based systems are sustainable in long-term remediation due to continuous generation of iron corrosion products The development of a novel kinetic model that accounts for the dynamic generation of iron corrosion products (FeCPs) represents a significant advancement in understanding phosphate (PO 4 3– ) removal by metallic iron (Fe⁰). While Fe⁰ has been utilized as a reactive material for phosphate removal, existing studies have largely overlooked the critical role of in-situ generated FeCPs in the removal process. This study aims to address this gap by developing a kinetic model for phosphate removal in Fe 0 /H 2 O systems while considering the dynamic nature of Fe° corrosion or FeCPs generation under natural conditions (neutral pH ∼7, 25°C). It integrates Fe⁰ corrosion, FeCPs precipitation, and phosphate removal via adsorption, complexation, and precipitation. Batch experiments using 4.5 g/L Fe 0 , and an initial PO 4 3– concentration of 10.0 mg/L were conducted to validate the proposed kinetic model. The model achieved high fitting accuracy (R² = 0.90), capturing the unique "slow-start" phase of PO 4 3– removal. It outperforms pseudo-first-order (R² = 0.72) and pseudo-second-order (R² = 0.71) models. Sensitivity analyses confirm Fe⁰ corrosion, not chemisorption or diffusion, is the rate-limiting step. Long-term simulations (100 days) show that Fe⁰-based systems outperform conventional adsorbents due to continuous FeCPs generation. The model establishes a reliable predictive framework for designing and optimizing Fe⁰-based water remediation technologies.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials Advances
Published
2026-02-01
DOI
https://doi.org/10.1016/j.hazadv.2026.101089
Primary Topic
Phosphorus and nutrient management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Process of phosphate removal in Fe0/H2O systems: A novel kinetic model considering iron corrosion at neutral pH

Chicgoua Noubactep, Huichen Yang, Bernard Konadu Amoah
Journal of Hazardous Materials Advances
Phosphorus and nutrient management
article

Process of phosphate removal in Fe0/H2O systems: A novel kinetic model considering iron corrosion at neutral pH

Chicgoua Noubactep, Huichen Yang, Bernard Konadu Amoah
article en

Abstract

• A kinetic model considering dynamics of Fe 0 corrosion is developed for Fe 0 /H 2 O systems • The model outperforms conventional kinetic models in describing phosphate removal • Iron corrosion is the rate-limiting step for phosphate removal in Fe 0 /H 2 O systems at neutral pH • Fe 0 -based systems are sustainable in long-term remediation due to continuous generation of iron corrosion products The development of a novel kinetic model that accounts for the dynamic generation of iron corrosion products (FeCPs) represents a significant advancement in understanding phosphate (PO 4 3– ) removal by metallic iron (Fe⁰). While Fe⁰ has been utilized as a reactive material for phosphate removal, existing studies have largely overlooked the critical role of in-situ generated FeCPs in the removal process. This study aims to address this gap by developing a kinetic model for phosphate removal in Fe 0 /H 2 O systems while considering the dynamic nature of Fe° corrosion or FeCPs generation under natural conditions (neutral pH ∼7, 25°C). It integrates Fe⁰ corrosion, FeCPs precipitation, and phosphate removal via adsorption, complexation, and precipitation. Batch experiments using 4.5 g/L Fe 0 , and an initial PO 4 3– concentration of 10.0 mg/L were conducted to validate the proposed kinetic model. The model achieved high fitting accuracy (R² = 0.90), capturing the unique "slow-start" phase of PO 4 3– removal. It outperforms pseudo-first-order (R² = 0.72) and pseudo-second-order (R² = 0.71) models. Sensitivity analyses confirm Fe⁰ corrosion, not chemisorption or diffusion, is the rate-limiting step. Long-term simulations (100 days) show that Fe⁰-based systems outperform conventional adsorbents due to continuous FeCPs generation. The model establishes a reliable predictive framework for designing and optimizing Fe⁰-based water remediation technologies.

Journal of Hazardous Materials AdvancesVol. 21
Xi'an University of Architecture and Technology (CN), Hohai University (CN), Kwame Nkrumah University of Science and Technology (GH), University of Göttingen (DE)
Responsible consumption and production
Openalex Percentile: Top 50%
Phosphorus and nutrient management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.