EEG and EMG dataset for analyzing movement-related cortical potentials in hand gesture tasks

This dataset contains electroencephalography (EEG) and electromyography (EMG) recordings acquired during the execution of specific motor tasks aimed at eliciting movement-related cortical potentials (MRCP). The goal is to provide an accessible resource for research in brain-computer interfaces (BCI), neurorehabilitation, and EEG-based prosthetic control. Data were collected from 40 healthy participants aged 18-30 years across five sessions, each comprising ten right-hand fist closure movements, guided by a custom Python-based visual interface. EEG signals were recorded using a 32-channel EMOTIV Flex 2 wireless system following the international 10-10 system, with a sampling rate of 128 Hz and electrode placement focused on the central cortical areas. All recordings, including raw EEG, raw EMG, and event triggers synchronized with the visual interface, were stored in .CSV format. To demonstrate that the EEG recordings in the dataset contain sufficient low-frequency information for MRCP analysis, we applied a standard preprocessing pipeline consisting of a common average reference (CAR), a Anti-Laplacian spatial filter, and a 0.1-1 Hz Butterworth band-pass filter. This procedure was used only for internal validation<b>,</b> allowing us to visualize the expected MRCP components from the nine motor-related electrodes. It is important to emphasize that these processed signals are not included in the database. The public dataset contains only the raw EEG and EMG recordings, so that users may apply their preferred preprocessing and analysis methods. The dataset was collected under controlled laboratory conditions at the Medical Devices Laboratory, Universidad Autónoma de Guadalajara, and represents a valuable contribution to the understanding and application of MRCP in BCI research.

Authors

Institutions

Publication Details

Journal
Data in Brief
Published
2026-02-17
DOI
https://doi.org/10.1016/j.dib.2026.112596
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EEG and EMG dataset for analyzing movement-related cortical potentials in hand gesture tasks

Francisco J. Alvarado‐Rodríguez, Hugo Vélez‐Pérez, Rebeca Romo‐Vázquez, Fernanda Rosas-Agraz et al.
Data in Brief
EEG and Brain-Computer Interfaces
article

EEG and EMG dataset for analyzing movement-related cortical potentials in hand gesture tasks

Francisco J. Alvarado‐Rodríguez, Hugo Vélez‐Pérez, Rebeca Romo‐Vázquez, Fernanda Rosas-Agraz, Fernanda Reyes-Jiménez, Eduardo Macias-Naranjo, Erick Guzmán-Quezada
article en

Abstract

This dataset contains electroencephalography (EEG) and electromyography (EMG) recordings acquired during the execution of specific motor tasks aimed at eliciting movement-related cortical potentials (MRCP). The goal is to provide an accessible resource for research in brain-computer interfaces (BCI), neurorehabilitation, and EEG-based prosthetic control. Data were collected from 40 healthy participants aged 18-30 years across five sessions, each comprising ten right-hand fist closure movements, guided by a custom Python-based visual interface. EEG signals were recorded using a 32-channel EMOTIV Flex 2 wireless system following the international 10-10 system, with a sampling rate of 128 Hz and electrode placement focused on the central cortical areas. All recordings, including raw EEG, raw EMG, and event triggers synchronized with the visual interface, were stored in .CSV format. To demonstrate that the EEG recordings in the dataset contain sufficient low-frequency information for MRCP analysis, we applied a standard preprocessing pipeline consisting of a common average reference (CAR), a Anti-Laplacian spatial filter, and a 0.1-1 Hz Butterworth band-pass filter. This procedure was used only for internal validation<b>,</b> allowing us to visualize the expected MRCP components from the nine motor-related electrodes. It is important to emphasize that these processed signals are not included in the database. The public dataset contains only the raw EEG and EMG recordings, so that users may apply their preferred preprocessing and analysis methods. The dataset was collected under controlled laboratory conditions at the Medical Devices Laboratory, Universidad Autónoma de Guadalajara, and represents a valuable contribution to the understanding and application of MRCP in BCI research.

Data in BriefVol. 65
Universidad Autónoma de Guadalajara (MX), Universidad de Guadalajara (MX)
Partnerships for the goals
Openalex Percentile: Top 54%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.