Intrinsic atomic calibration of oscillating magnetic fields in ULF and VLF bands

We present a method for absolute calibration of received radio frequency in the ultra-low frequency and very low frequency range. This is achieved with the use of a radio frequency optically pumped magnetometer. We describe a method using an optically pumped sample where the RF broadening of the Cs magnetic resonance allows the magnitude of the received field to be calibrated against the ground-state gyromagnetic ratio of the Cs atoms. This frequency-based calibration avoids the geometric and electrostatic response functions that affect inductive sensors, such as fluxgates, search coils, and SQUID magnetometers. We demonstrate the calibration of magnetic measurement using oscillating magnetic fields in the 300 Hz-20 kHz range and a sensor noise floor of 15 fT Hz-1/2. This radio frequency sensor may be used as a widely tunable narrowband receiver for communication, ranging, or penetrative conductivity imaging.

Publication Details

Journal
Review of Scientific Instruments
Published
2026-02-01
DOI
https://doi.org/10.1063/5.0304991
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intrinsic atomic calibration of oscillating magnetic fields in ULF and VLF bands

Review of Scientific Instruments
Atomic and Subatomic Physics Research
article

Intrinsic atomic calibration of oscillating magnetic fields in ULF and VLF bands

article en

Abstract

We present a method for absolute calibration of received radio frequency in the ultra-low frequency and very low frequency range. This is achieved with the use of a radio frequency optically pumped magnetometer. We describe a method using an optically pumped sample where the RF broadening of the Cs magnetic resonance allows the magnitude of the received field to be calibrated against the ground-state gyromagnetic ratio of the Cs atoms. This frequency-based calibration avoids the geometric and electrostatic response functions that affect inductive sensors, such as fluxgates, search coils, and SQUID magnetometers. We demonstrate the calibration of magnetic measurement using oscillating magnetic fields in the 300 Hz-20 kHz range and a sensor noise floor of 15 fT Hz-1/2. This radio frequency sensor may be used as a widely tunable narrowband receiver for communication, ranging, or penetrative conductivity imaging.

Review of Scientific InstrumentsVol. 97(2)
Affordable and clean energy
Openalex Percentile: Top 51%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Intrinsic atomic calibration of oscillating magnetic fields in ULF and VLF bands · Review of Scientific Instruments (2026) | TGRS Research Map | TGRS