When ICDs Do Not Deliver: The Unseen Burden of Untreated Arrhythmias

ICDs are implanted to treat sudden arrhythmic death by treating episodes of ventricular arrhythmia (VA). Despite this primary function, patients can still die with a functioning ICD due to untreated VA. The purpose of this review is to examine the causes and implications of ICD failures in detection and therapy delivery during VA and assess post-mortem interrogation practices and literature. The literature, adverse event reports, and the authors' own internal data were reviewed to identify causes of ICD non-therapy. Signal-related, functional, algorithmic and myocardial undersensing were identified as contributors, along with episodes of failed defibrillation/cardioversion. Contemporary ICD programming prioritises specificity but may compromise sensitivity. Post-mortem interrogation is rare, under-utilised and has no standardisation, despite reports of ICD failure being the cause of death in up to 25% of cases. To conclude, failure to interrogate ICDs after death risks missing fatal undersensing. Systematic post-mortem analysis is proposed as the cardiac equivalent of aviation's black box, which is critical for learning and sudden arrhythmic death prevention.

Authors

Institutions

Publication Details

Journal
Arrhythmia & Electrophysiology Review
Published
2026-02-17
DOI
https://doi.org/10.15420/aer.2025.59
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

When ICDs Do Not Deliver: The Unseen Burden of Untreated Arrhythmias

Charles D. Swerdlow, P. Lambiase, Christopher Monkhouse, Robert G. Hauser et al.
Arrhythmia & Electrophysiology Review
Cardiac electrophysiology and arrhythmias
article

When ICDs Do Not Deliver: The Unseen Burden of Untreated Arrhythmias

Charles D. Swerdlow, P. Lambiase, Christopher Monkhouse, Robert G. Hauser, R Hunter, Syed Ahsan
article en

Abstract

ICDs are implanted to treat sudden arrhythmic death by treating episodes of ventricular arrhythmia (VA). Despite this primary function, patients can still die with a functioning ICD due to untreated VA. The purpose of this review is to examine the causes and implications of ICD failures in detection and therapy delivery during VA and assess post-mortem interrogation practices and literature. The literature, adverse event reports, and the authors' own internal data were reviewed to identify causes of ICD non-therapy. Signal-related, functional, algorithmic and myocardial undersensing were identified as contributors, along with episodes of failed defibrillation/cardioversion. Contemporary ICD programming prioritises specificity but may compromise sensitivity. Post-mortem interrogation is rare, under-utilised and has no standardisation, despite reports of ICD failure being the cause of death in up to 25% of cases. To conclude, failure to interrogate ICDs after death risks missing fatal undersensing. Systematic post-mortem analysis is proposed as the cardiac equivalent of aviation's black box, which is critical for learning and sudden arrhythmic death prevention.

Arrhythmia & Electrophysiology ReviewVol. 15
St Bartholomew's Hospital (GB), Minneapolis Heart Institute Foundation (US), Cedars-Sinai Smidt Heart Institute (US)
Good health and well-being
Openalex Percentile: Top 55%
Cardiac electrophysiology and arrhythmias
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.