A Preliminary Mechanical Evaluation of a Newly Developed Polyaxial Locking Mechanism for a Distal Radius Plate

Background/Objectives: Polyaxial locking systems for distal radius plates differ among manufacturers, and the mechanical strength of their locking mechanism is rarely disclosed. This study aimed to perform a preliminary mechanical evaluation of a newly developed polyaxial locking mechanism and to investigate its strength at different screw insertion angles. Methods: The polyaxial locking mechanism was evaluated via static load testing at three screw insertion angles until failure, and the maximum bending moment was measured. Loading was performed via cantilever bending to generate a bending moment in the polyaxial locking mechanism. The maximum bending moments of the insertion angles of 10° for the holes in the distal rows were investigated for significant differences. Results: Maximum bending moments significantly decreased as the screw insertion angle increased, with reductions of approximately 50% at 5° and 10° compared with 0°. At a 10° insertion angle, variation in ultimate strength was observed among screw hole in the distal row. The failure mechanism was loosening of the locking screws in all tests. Conclusions: The maximum bending moment of the polyaxial locking mechanism decreased with increasing locking screw insertion angle, highlighting the importance of insertion angle in polyaxial locking plate fixation.

Authors

Institutions

Publication Details

Journal
Biomechanics
Published
2026-02-17
DOI
https://doi.org/10.3390/biomechanics6010022
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Preliminary Mechanical Evaluation of a Newly Developed Polyaxial Locking Mechanism for a Distal Radius Plate

Koji Hatano, Yutaka Maki, Kazuhito Yanabashi, K. Moriya et al.
Biomechanics
Orthopedic Surgery and Rehabilitation
article

A Preliminary Mechanical Evaluation of a Newly Developed Polyaxial Locking Mechanism for a Distal Radius Plate

Koji Hatano, Yutaka Maki, Kazuhito Yanabashi, K. Moriya, Takuya Yoda, Hiroyuki Kawashima
article en

Abstract

Background/Objectives: Polyaxial locking systems for distal radius plates differ among manufacturers, and the mechanical strength of their locking mechanism is rarely disclosed. This study aimed to perform a preliminary mechanical evaluation of a newly developed polyaxial locking mechanism and to investigate its strength at different screw insertion angles. Methods: The polyaxial locking mechanism was evaluated via static load testing at three screw insertion angles until failure, and the maximum bending moment was measured. Loading was performed via cantilever bending to generate a bending moment in the polyaxial locking mechanism. The maximum bending moments of the insertion angles of 10° for the holes in the distal rows were investigated for significant differences. Results: Maximum bending moments significantly decreased as the screw insertion angle increased, with reductions of approximately 50% at 5° and 10° compared with 0°. At a 10° insertion angle, variation in ultimate strength was observed among screw hole in the distal row. The failure mechanism was loosening of the locking screws in all tests. Conclusions: The maximum bending moment of the polyaxial locking mechanism decreased with increasing locking screw insertion angle, highlighting the importance of insertion angle in polyaxial locking plate fixation.

BiomechanicsVol. 6(1)
Niigata Seiryo University (JP), Niigata Cancer Center Hospital (JP), Niigata University Medical and Dental Hospital (JP)
Openalex Percentile: Top 52%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Preliminary Mechanical Evaluation of a Newly Developed Polyaxial Locking Mechanism for a Distal Radius Plate — Koji Hatano, Yutaka Maki, et al. · Biomechanics (2026) | TGRS Research Map | TGRS