The Pacemaker Cable as an Unexpected Cause of Recurrent Pulmonary Embolism

Recurrent pulmonary embolism (PE) is uncommon. We report a 39-year-old man with a pacemaker who developed recurrent PEs while receiving rivaroxaban, warfarin, and therapeutic enoxaparin. Evaluation for autoimmunity and thrombophilia was negative. Each episode was preceded by fever, malaise, and myalgia. During admission, 18-fluorodeoxyglucose positron emission tomography–computed tomography (18FDG PET/CT) showed focal uptake (maximum standardized uptake value, 2.3) along the right-ventricular pacemaker lead, suggesting device-related infection or thrombosis. Transvenous extraction failed; subsequently, surgical removal was performed. Cultures remained negative. This case highlights pacemaker-associated infection as a treatable cause of septic embolization and underscores the diagnostic value of 18FDG PET/CT in recurrent PE.

Authors

Institutions

Publication Details

Journal
Annals of Internal Medicine Clinical Cases
Published
2026-02-01
DOI
https://doi.org/10.7326/aimcc.2025.1115
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Pacemaker Cable as an Unexpected Cause of Recurrent Pulmonary Embolism

Wagner Tadeu Jurevicius Nascimento, Tan Chen Wu, R. Souza, W. Salibe-Filho et al.
Annals of Internal Medicine Clinical Cases
Venous Thromboembolism Diagnosis and Management
article

The Pacemaker Cable as an Unexpected Cause of Recurrent Pulmonary Embolism

Wagner Tadeu Jurevicius Nascimento, Tan Chen Wu, R. Souza, W. Salibe-Filho, José Leonidas Alves-Junior, Gabriel Navarrete
article en

Abstract

Recurrent pulmonary embolism (PE) is uncommon. We report a 39-year-old man with a pacemaker who developed recurrent PEs while receiving rivaroxaban, warfarin, and therapeutic enoxaparin. Evaluation for autoimmunity and thrombophilia was negative. Each episode was preceded by fever, malaise, and myalgia. During admission, 18-fluorodeoxyglucose positron emission tomography–computed tomography (18FDG PET/CT) showed focal uptake (maximum standardized uptake value, 2.3) along the right-ventricular pacemaker lead, suggesting device-related infection or thrombosis. Transvenous extraction failed; subsequently, surgical removal was performed. Cultures remained negative. This case highlights pacemaker-associated infection as a treatable cause of septic embolization and underscores the diagnostic value of 18FDG PET/CT in recurrent PE.

Annals of Internal Medicine Clinical CasesVol. 5(2)
Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (BR)
Good health and well-being
Openalex Percentile: Top 57%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.