Non invasive blood glucose estimation using green light photoplethysmography and machine learning

Non-communicable diseases, such as diabetes, are the leading cause of mortality worldwide. Effective diabetes management is crucial for ensuring the well-being of diabetics. Existing glucose monitoring technologies are often invasive and uncomfortable, eliciting anxiety among patients. Non-invasive procedures offer a promising solution for these issues, but their widespread adoption is restricted by cost and accuracy constraints. This study investigates the use of green light Photoplethysmography (PPG) signals for non-invasive blood glucose monitoring. A custom-designed PPG acquisition setup was developed to collect PPG data from 80 subjects under controlled conditions. Simultaneously, reference capillary blood glucose readings were obtained using a lancing device to serve as the gold standard. Signals were enhanced by applying different processing techniques and 32 features were extracted, which were scaled and subjected to correlation analysis to retain the highly correlated features. Feature engineering further optimized the feature set, which was then used to train and validate regression models. Model performance was evaluated using R<sup>2</sup> (coefficient of determination), mean absolute error (MAE), and bias analysis across glucose ranges. Among the tested models, the Random Forest Regression (RFR) showed the best performance with an R<sup>2</sup> value of 0.92 and MAE of 4.8 mg/dL. Predicted glucose levels demonstrated minimal bias across glucose ranges, with mean differences of -5.11 ± 0.80 mg/dL (<90 mg/dL), -3.68 ± 1.24 mg/dL (90-120 mg/dL), and -5.61 ± 0.75 mg/dL (≥120 mg/dL). The findings demonstrate that PPG signals in the green light spectrum effectively reflect blood glucose levels, supporting their potential for non-invasive glucose monitoring.

Authors

Institutions

Publication Details

Journal
Frontiers in Digital Health
Published
2026-02-17
DOI
https://doi.org/10.3389/fdgth.2026.1705086
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non invasive blood glucose estimation using green light photoplethysmography and machine learning

Theodoros N. Arvanitis, Abdul Qadeer Khan, Saadullah Farooq Abbasi, Khadija Khan et al.
Frontiers in Digital Health
Non-Invasive Vital Sign Monitoring
article

Non invasive blood glucose estimation using green light photoplethysmography and machine learning

Theodoros N. Arvanitis, Abdul Qadeer Khan, Saadullah Farooq Abbasi, Khadija Khan, Laraib Malik
article en

Abstract

Non-communicable diseases, such as diabetes, are the leading cause of mortality worldwide. Effective diabetes management is crucial for ensuring the well-being of diabetics. Existing glucose monitoring technologies are often invasive and uncomfortable, eliciting anxiety among patients. Non-invasive procedures offer a promising solution for these issues, but their widespread adoption is restricted by cost and accuracy constraints. This study investigates the use of green light Photoplethysmography (PPG) signals for non-invasive blood glucose monitoring. A custom-designed PPG acquisition setup was developed to collect PPG data from 80 subjects under controlled conditions. Simultaneously, reference capillary blood glucose readings were obtained using a lancing device to serve as the gold standard. Signals were enhanced by applying different processing techniques and 32 features were extracted, which were scaled and subjected to correlation analysis to retain the highly correlated features. Feature engineering further optimized the feature set, which was then used to train and validate regression models. Model performance was evaluated using R<sup>2</sup> (coefficient of determination), mean absolute error (MAE), and bias analysis across glucose ranges. Among the tested models, the Random Forest Regression (RFR) showed the best performance with an R<sup>2</sup> value of 0.92 and MAE of 4.8 mg/dL. Predicted glucose levels demonstrated minimal bias across glucose ranges, with mean differences of -5.11 ± 0.80 mg/dL (<90 mg/dL), -3.68 ± 1.24 mg/dL (90-120 mg/dL), and -5.61 ± 0.75 mg/dL (≥120 mg/dL). The findings demonstrate that PPG signals in the green light spectrum effectively reflect blood glucose levels, supporting their potential for non-invasive glucose monitoring.

Frontiers in Digital HealthVol. 8
Riphah International University (PK), University of Birmingham (GB)
Good health and well-being
Openalex Percentile: Top 53%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.