Salvaging a Failed <scp>PreserFlo MicroShunt</scp> Using a Telescopic Tube‐in‐Tube Connection Technique With an <scp>EyePlate</scp> Implant: A Case Report

The PreserFlo MicroShunt is a subconjunctival glaucoma drainage device designed to reduce intraocular pressure (IOP) via a minimally invasive approach. However, device failure due to bleb fibrosis remains a significant clinical challenge, especially when initial revision surgery is unsuccessful. We present a 75-year-old male with pseudoexfoliation glaucoma who previously underwent PreserFlo MicroShunt implantation and a subsequent revision procedure at an outside institution. Due to persistently elevated IOP and progressive visual decline, he was referred to our center for further management. A novel telescopic tube-to-tube connection was performed between the existing PreserFlo MicroShunt and a new EyePlate-200 implant, utilizing and preserving the original scleral tunnel. Postoperative IOP decreased from 40 to 10 mmHg and remained stable without complications during a 6-month follow-up. A surgical video is provided as Video 1. This case illustrates a novel telescopic tube-to-tube connection technique to restore aqueous outflow in cases of PreserFlo MicroShunt failure. By preserving the original scleral tunnel, this approach may offer a minimally invasive alternative to complete device explantation or conventional tube shunt surgery.

Authors

Institutions

Publication Details

Journal
Clinical Case Reports
Published
2026-02-01
DOI
https://doi.org/10.1002/ccr3.72072
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Salvaging a Failed PreserFlo MicroShunt Using a Telescopic Tube‐in‐Tube Connection Technique With an EyePlate Implant: A Case Report

Karl Mercieca, Qian Wei, Frank G. Holz
Clinical Case Reports
Glaucoma and retinal disorders
article

Salvaging a Failed PreserFlo MicroShunt Using a Telescopic Tube‐in‐Tube Connection Technique With an EyePlate Implant: A Case Report

Karl Mercieca, Qian Wei, Frank G. Holz
article en

Abstract

The PreserFlo MicroShunt is a subconjunctival glaucoma drainage device designed to reduce intraocular pressure (IOP) via a minimally invasive approach. However, device failure due to bleb fibrosis remains a significant clinical challenge, especially when initial revision surgery is unsuccessful. We present a 75-year-old male with pseudoexfoliation glaucoma who previously underwent PreserFlo MicroShunt implantation and a subsequent revision procedure at an outside institution. Due to persistently elevated IOP and progressive visual decline, he was referred to our center for further management. A novel telescopic tube-to-tube connection was performed between the existing PreserFlo MicroShunt and a new EyePlate-200 implant, utilizing and preserving the original scleral tunnel. Postoperative IOP decreased from 40 to 10 mmHg and remained stable without complications during a 6-month follow-up. A surgical video is provided as Video 1. This case illustrates a novel telescopic tube-to-tube connection technique to restore aqueous outflow in cases of PreserFlo MicroShunt failure. By preserving the original scleral tunnel, this approach may offer a minimally invasive alternative to complete device explantation or conventional tube shunt surgery.

Clinical Case ReportsVol. 14(2)
University of Bonn (DE), University Hospital Bonn (DE)
Openalex Percentile: Top 53%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Salvaging a Failed <scp>PreserFlo MicroShunt</scp> Using a Telescopic Tube‐in‐Tube Connection Technique With an <scp>EyePlate</scp> Implant: A Case Report — Karl Mercieca, Qian Wei, et al. · Clinical Case Reports (2026) | TGRS Research Map | TGRS