Acute measurement of flow‐mediated dilation following passive heating in adults: The confounding role of altered shear stress and baseline vasodilation

Changes in flow-mediated dilation (FMD) following acute heating are not well understood, appear protocol-specific, and may be better understood by additional measures of acute vasoactivity. This study investigated FMD responses before and after three different 30-min hot-water immersion conditions (40°C-Shoulder, 42°C-Waist, and 40°C-Waist) in 22 adults. Brachial artery diameter was recorded at baseline (D<sub>base</sub>), during the final 30 s of occlusion (D<sub>occ</sub>), and at peak post-occlusion (D<sub>peak</sub>). Allometrically scaled FMD%, and changes in diameter during occlusion (OIV), and from end-occlusion to peak diameter (FMD<sub>Docc</sub>) were calculated. Pre-occlusion shear rate was greater post-immersion in 40-Shoulder (p < 0.001) and 42-Waist (p < 0.001), but not 40-Waist (p = 0.13), with the largest increase observed in 40-Shoulder. Alongside this, D<sub>base</sub> increased (Δ0.4 ± 0.2 mm, p < 0.001) and FMD% decreased (Δ-3.9 ± 3.8%, p = 0.04) following immersion in 40°C-Shoulder only. Across all conditions, ΔFMD% was negatively associated with ΔD<sub>base</sub> (r<sub>rm</sub> = -0.47, p = 0.001). OIV% was the only vasoactivity metric to statistically differentiate between all conditions post-immersion (40°C-Shoulder: -8.1 ± 4.9%. 42°C-Waist: -3.0 ± 5.3%. 40°C-Waist: 1.1 ± 4.1%. p < 0.001). Post-heating FMD is confounded by heat-induced increases in baseline diameter, even after allometric scaling, while OIV% may provide complementary insight into acute vasoactivity following passive heating.

Authors

Institutions

Publication Details

Journal
Physiological Reports
Published
2026-02-01
DOI
https://doi.org/10.14814/phy2.70723
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Acute measurement of flow‐mediated dilation following passive heating in adults: The confounding role of altered shear stress and baseline vasodilation

Charles J. Steward, Campbell Menzies, Neil D. Clarke, Tom Cullen et al.
Physiological Reports
Thermoregulation and physiological responses
article

Acute measurement of flow‐mediated dilation following passive heating in adults: The confounding role of altered shear stress and baseline vasodilation

Charles J. Steward, Campbell Menzies, Neil D. Clarke, Tom Cullen, C. Douglas Thake
article en

Abstract

Changes in flow-mediated dilation (FMD) following acute heating are not well understood, appear protocol-specific, and may be better understood by additional measures of acute vasoactivity. This study investigated FMD responses before and after three different 30-min hot-water immersion conditions (40°C-Shoulder, 42°C-Waist, and 40°C-Waist) in 22 adults. Brachial artery diameter was recorded at baseline (D<sub>base</sub>), during the final 30 s of occlusion (D<sub>occ</sub>), and at peak post-occlusion (D<sub>peak</sub>). Allometrically scaled FMD%, and changes in diameter during occlusion (OIV), and from end-occlusion to peak diameter (FMD<sub>Docc</sub>) were calculated. Pre-occlusion shear rate was greater post-immersion in 40-Shoulder (p < 0.001) and 42-Waist (p < 0.001), but not 40-Waist (p = 0.13), with the largest increase observed in 40-Shoulder. Alongside this, D<sub>base</sub> increased (Δ0.4 ± 0.2 mm, p < 0.001) and FMD% decreased (Δ-3.9 ± 3.8%, p = 0.04) following immersion in 40°C-Shoulder only. Across all conditions, ΔFMD% was negatively associated with ΔD<sub>base</sub> (r<sub>rm</sub> = -0.47, p = 0.001). OIV% was the only vasoactivity metric to statistically differentiate between all conditions post-immersion (40°C-Shoulder: -8.1 ± 4.9%. 42°C-Waist: -3.0 ± 5.3%. 40°C-Waist: 1.1 ± 4.1%. p < 0.001). Post-heating FMD is confounded by heat-induced increases in baseline diameter, even after allometric scaling, while OIV% may provide complementary insight into acute vasoactivity following passive heating.

Physiological ReportsVol. 14(4)
Birmingham City University (GB), University of Nottingham (GB), Coventry University (GB), Cardiff Metropolitan University (GB)
Coventry University
Clean water and sanitation
Openalex Percentile: Top 51%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.