The Impact of Irrigating Solutions on the Tensile Strength of Silicone Breast Implants: A Comparative In Vitro Analysis for Intraoperative use

<b>Introduction:</b> The durability of silicone breast implants is critical for successful aesthetic and reconstructive outcomes. Intraoperative breast pocket irrigation is routinely performed to reduce infection and capsular contracture, but the effect of commonly used irrigants on implant shell integrity remains unclear. <b>Methods:</b> Silicone breast implant shells from Mentor and Allergan Natrelle were sectioned into 2.5 × 2.5 cm samples and randomly allocated to 5 irrigant groups: 0.9% normal saline, triple antibiotic solution (clindamycin, cefazolin, gentamicin), 0.05% chlorhexidine gluconate (Irrisept<sup>®</sup>), 10% povidone-iodine (Betadine<sup>®</sup>), and Poloxamer 188 (SAF-Clens<sup>®</sup> AF). Each sample was immersed in its respective irrigant for 60 s then tested for tensile strength using a commercial tensiometer with a 1.0 cm displacement. Data were analyzed using one-way ANOVA with Tukey's HSD post hoc testing. <b>Results:</b> Average preimmersion tensile strength was 8.58 N. Postimmersion tensile strengths were 8.25 N (saline), 8.94 (triple antibiotic), 8.84 N (chlorhexidine gluconate), 8.08 N (povidone-iodine), and 7.41 N (Poloxamer 188). No statistically significant differences were found among groups (ANOVA, <i>P</i> = .085), though a trend toward reduced tensile strength following Poloxamer exposure was observed. <b>Conclusions:</b> Normal saline, triple antibiotic solution, chlorhexidine gluconate, and povidone-iodine did not significantly affect the tensile strength of silicone breast implant shells. Poloxamer 188, however, showed a trend toward greater reduction in tensile strength and should be thoroughly rinsed prior to implant placement. These findings support the safe use of conventional antiseptic and antibiotic irrigants with minimal impact on implant mechanical integrity.

Authors

Institutions

Publication Details

Journal
Plastic Surgery
Published
2026-02-17
DOI
https://doi.org/10.1177/22925503261419807
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Irrigating Solutions on the Tensile Strength of Silicone Breast Implants: A Comparative In Vitro Analysis for Intraoperative use

Kylie McMath, Subhas Gupta, Leah E. Thomas, James Tran
Plastic Surgery
Breast Implant and Reconstruction
article

The Impact of Irrigating Solutions on the Tensile Strength of Silicone Breast Implants: A Comparative In Vitro Analysis for Intraoperative use

Kylie McMath, Subhas Gupta, Leah E. Thomas, James Tran
article en

Abstract

<b>Introduction:</b> The durability of silicone breast implants is critical for successful aesthetic and reconstructive outcomes. Intraoperative breast pocket irrigation is routinely performed to reduce infection and capsular contracture, but the effect of commonly used irrigants on implant shell integrity remains unclear. <b>Methods:</b> Silicone breast implant shells from Mentor and Allergan Natrelle were sectioned into 2.5 × 2.5 cm samples and randomly allocated to 5 irrigant groups: 0.9% normal saline, triple antibiotic solution (clindamycin, cefazolin, gentamicin), 0.05% chlorhexidine gluconate (Irrisept<sup>®</sup>), 10% povidone-iodine (Betadine<sup>®</sup>), and Poloxamer 188 (SAF-Clens<sup>®</sup> AF). Each sample was immersed in its respective irrigant for 60 s then tested for tensile strength using a commercial tensiometer with a 1.0 cm displacement. Data were analyzed using one-way ANOVA with Tukey's HSD post hoc testing. <b>Results:</b> Average preimmersion tensile strength was 8.58 N. Postimmersion tensile strengths were 8.25 N (saline), 8.94 (triple antibiotic), 8.84 N (chlorhexidine gluconate), 8.08 N (povidone-iodine), and 7.41 N (Poloxamer 188). No statistically significant differences were found among groups (ANOVA, <i>P</i> = .085), though a trend toward reduced tensile strength following Poloxamer exposure was observed. <b>Conclusions:</b> Normal saline, triple antibiotic solution, chlorhexidine gluconate, and povidone-iodine did not significantly affect the tensile strength of silicone breast implant shells. Poloxamer 188, however, showed a trend toward greater reduction in tensile strength and should be thoroughly rinsed prior to implant placement. These findings support the safe use of conventional antiseptic and antibiotic irrigants with minimal impact on implant mechanical integrity.

Plastic Surgery
Loma Linda University (US)
Openalex Percentile: Top 53%
Breast Implant and Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.