Research on the Fretting Wear of Braided Units in Nonvascular Stents

This study aimed to analyze the fretting wear between the wires of braided nonvascular stents implanted in pathologically narrowed nonvascular lumens, using finite-element numerical simulation and experimental methods. A suitable and representative braided unit from a typical esophageal stent was selected to simulate fretting wear under two distinct pathological tissue growth patterns within the esophagus: uniform circumferential growth (CASE1) and unilateral growth (CASE2). The accuracy of the simulation was verified by comparing it with experimental data, and the profiles and morphological features of the wear scars were meticulously analyzed using scanning electron microscopy. The study found that the wear between the wires of the braided unit is primarily sliding friction, with mutual influence across the four contact regions, resulting in approximately elliptical wear scars. As the number of cycles increased, the wear depth and volume loss gradually increased, demonstrating the cumulative effect of wear over time. CASE2 exhibited higher normal contact forces across all contact areas compared to CASE1, resulting in greater wear depths and volume loss. After 1 million cycles, distinct wear marks were noted in the wire contact areas without any significant cracks. Discounting the influence of the acid-base wet environment, the risk of stent fatigue failure attributed to fretting wear within 3 years is assessed as low. Nevertheless, the wear debris generated on the worn surfaces poses a potential risk for inducing local inflammation, a factor that warrants further investigation. The study results are valuable for improving stent design, ultimately enhancing patient safety and treatment efficacy.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2026-02-01
DOI
https://doi.org/10.1002/jbm.b.70042
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Fretting Wear of Braided Units in Nonvascular Stents

Cuizhen Pan, Mengting Li, Xiaoyu Ni, Yuxuan Li
Journal of Biomedical Materials Research Part B Applied Biomaterials
Orthopaedic implants and arthroplasty
article

Research on the Fretting Wear of Braided Units in Nonvascular Stents

Cuizhen Pan, Mengting Li, Xiaoyu Ni, Yuxuan Li
article en

Abstract

This study aimed to analyze the fretting wear between the wires of braided nonvascular stents implanted in pathologically narrowed nonvascular lumens, using finite-element numerical simulation and experimental methods. A suitable and representative braided unit from a typical esophageal stent was selected to simulate fretting wear under two distinct pathological tissue growth patterns within the esophagus: uniform circumferential growth (CASE1) and unilateral growth (CASE2). The accuracy of the simulation was verified by comparing it with experimental data, and the profiles and morphological features of the wear scars were meticulously analyzed using scanning electron microscopy. The study found that the wear between the wires of the braided unit is primarily sliding friction, with mutual influence across the four contact regions, resulting in approximately elliptical wear scars. As the number of cycles increased, the wear depth and volume loss gradually increased, demonstrating the cumulative effect of wear over time. CASE2 exhibited higher normal contact forces across all contact areas compared to CASE1, resulting in greater wear depths and volume loss. After 1 million cycles, distinct wear marks were noted in the wire contact areas without any significant cracks. Discounting the influence of the acid-base wet environment, the risk of stent fatigue failure attributed to fretting wear within 3 years is assessed as low. Nevertheless, the wear debris generated on the worn surfaces poses a potential risk for inducing local inflammation, a factor that warrants further investigation. The study results are valuable for improving stent design, ultimately enhancing patient safety and treatment efficacy.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 114(2)
Nanjing Forestry University (CN), Collaborative Innovation Center of Advanced Microstructures (CN)
Openalex Percentile: Top 53%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on the Fretting Wear of Braided Units in Nonvascular Stents — Cuizhen Pan, Mengting Li, et al. · Journal of Biomedical Materials Research Part B Applied Biomaterials (2026) | TGRS Research Map | TGRS