Comb-mode sweeping in a 650 nm–1030 nm astrocomb

Astrocombs are promising calibration sources for high-resolution astronomical spectrographs, offering stable, uniformly spaced calibration lines whose positions are traceable to an atomic frequency reference. Most spectrograph pixels fall in the gaps between astrocomb lines, remaining uninterrogated by the calibration light; however, it is becoming clear that detector inhomogeneities and intra-order variations in the spectrograph performance make it important to characterize the entire detector area to obtain the best radial-velocity precision. Here, this requirement is fulfilled by the demonstration of an astrocomb architecture in which lines can be swept in any chosen increment in frequency. Based on Fabry-Pérot filtering of a primary comb with a 1 GHz spacing, the astrocomb employs feed-forward locking to overlap a single-frequency laser onto a chosen primary comb line, a process that precisely selects which subset of primary comb modes will be transmitted by the Fabry-Pérot cavity. Operating from 650-1030 nm, and exhibiting continuous performance for >12 hours, the system demonstrates the long-term stability required by a practical astrocomb, while providing the fine sampling of the spectrograph instrument function likely to be necessary for achieving radial-velocity precisions supporting Earth-like exoplanet detection.

Authors

Publication Details

Journal
Optics Express
Published
2026-02-17
DOI
https://doi.org/10.1364/oe.588310
Primary Topic
Advanced Fiber Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comb-mode sweeping in a 650 nm–1030 nm astrocomb

Jake M. Charsley, Richard A. McCracken, Yuk Shan Cheng, Kamalesh Dadi et al.
Optics Express
Advanced Fiber Laser Technologies
article

Comb-mode sweeping in a 650 nm–1030 nm astrocomb

Jake M. Charsley, Richard A. McCracken, Yuk Shan Cheng, Kamalesh Dadi, W.H. Newman, Derryck Reid
article en

Abstract

Astrocombs are promising calibration sources for high-resolution astronomical spectrographs, offering stable, uniformly spaced calibration lines whose positions are traceable to an atomic frequency reference. Most spectrograph pixels fall in the gaps between astrocomb lines, remaining uninterrogated by the calibration light; however, it is becoming clear that detector inhomogeneities and intra-order variations in the spectrograph performance make it important to characterize the entire detector area to obtain the best radial-velocity precision. Here, this requirement is fulfilled by the demonstration of an astrocomb architecture in which lines can be swept in any chosen increment in frequency. Based on Fabry-Pérot filtering of a primary comb with a 1 GHz spacing, the astrocomb employs feed-forward locking to overlap a single-frequency laser onto a chosen primary comb line, a process that precisely selects which subset of primary comb modes will be transmitted by the Fabry-Pérot cavity. Operating from 650-1030 nm, and exhibiting continuous performance for >12 hours, the system demonstrates the long-term stability required by a practical astrocomb, while providing the fine sampling of the spectrograph instrument function likely to be necessary for achieving radial-velocity precisions supporting Earth-like exoplanet detection.

Optics ExpressVol. 34(5)
Affordable and clean energy
Openalex Percentile: Top 51%
Advanced Fiber Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.