Development of dynamic calibration system for high-frequency response evaluation of fast pressure-sensitive paint using cavity-induced flapping jet

A high-frequency dynamic calibration system for pressure-sensitive paint (PSP) was developed using cavity-induced jets. The dominant frequency for dynamic calibration was adjusted to the range of 9–16 kHz by scaling the cavity. The dominant flapping frequencies corresponding to different cavity lengths were identified. The distributions of pressure fluctuations across cavities were measured using fast PSP technology. An anodized-aluminum PSP (AA-PSP) with a free-based porphyrin luminophore (H $$_2$$ TCPP) was utilized for pressure measurement. Instantaneous pressure fields were measured by combining a high-frequency dual-pulse laser and a high-speed camera. The denoising technique combining filtering and singular value decomposition (SVD) was applied, and the dominant pressure fluctuation components were extracted. The spatially averaged pressure amplitude and the uniformity of the pressure fluctuation fields were evaluated based on SVD. Potentially optimal calibration regions, exhibiting both high amplitude and uniformity, were identified on the Pareto front. Among them, the region exhibiting the highest pressure amplitude was selected as the optimal calibration region, which is located around the downstream slot. A point-measurement system for dynamic calibration of PSPs was constructed. The dynamic calibration of fast PSPs was performed. The gain attenuation and phase delay in the range of 9–16 kHz were evaluated. The calibration results exhibit good continuity with those obtained below 9 kHz using an acoustic resonance tube system. The cut-off frequency of AA-H $$_2$$ TCPP and PC-Ru(dpp) $$_3$$ at -3 dB are approximately 19.9 kHz and 18.9 kHz, respectively.

Authors

Institutions

Publication Details

Journal
Experiments in Fluids
Published
2026-02-17
DOI
https://doi.org/10.1007/s00348-026-04188-0
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of dynamic calibration system for high-frequency response evaluation of fast pressure-sensitive paint using cavity-induced flapping jet

Taku Nonomura, Di Kong, Takayuki Nagata
Experiments in Fluids
Analytical Chemistry and Sensors
article

Development of dynamic calibration system for high-frequency response evaluation of fast pressure-sensitive paint using cavity-induced flapping jet

Taku Nonomura, Di Kong, Takayuki Nagata
article en

Abstract

A high-frequency dynamic calibration system for pressure-sensitive paint (PSP) was developed using cavity-induced jets. The dominant frequency for dynamic calibration was adjusted to the range of 9–16 kHz by scaling the cavity. The dominant flapping frequencies corresponding to different cavity lengths were identified. The distributions of pressure fluctuations across cavities were measured using fast PSP technology. An anodized-aluminum PSP (AA-PSP) with a free-based porphyrin luminophore (H $$_2$$ TCPP) was utilized for pressure measurement. Instantaneous pressure fields were measured by combining a high-frequency dual-pulse laser and a high-speed camera. The denoising technique combining filtering and singular value decomposition (SVD) was applied, and the dominant pressure fluctuation components were extracted. The spatially averaged pressure amplitude and the uniformity of the pressure fluctuation fields were evaluated based on SVD. Potentially optimal calibration regions, exhibiting both high amplitude and uniformity, were identified on the Pareto front. Among them, the region exhibiting the highest pressure amplitude was selected as the optimal calibration region, which is located around the downstream slot. A point-measurement system for dynamic calibration of PSPs was constructed. The dynamic calibration of fast PSPs was performed. The gain attenuation and phase delay in the range of 9–16 kHz were evaluated. The calibration results exhibit good continuity with those obtained below 9 kHz using an acoustic resonance tube system. The cut-off frequency of AA-H $$_2$$ TCPP and PC-Ru(dpp) $$_3$$ at -3 dB are approximately 19.9 kHz and 18.9 kHz, respectively.

Experiments in FluidsVol. 67(3)
Tohoku University (JP), Nagoya University (JP)
Openalex Percentile: Top 55%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of dynamic calibration system for high-frequency response evaluation of fast pressure-sensitive paint using cavity-induced flapping jet — Taku Nonomura, Di Kong, et al. · Experiments in Fluids (2026) | TGRS Research Map | TGRS