Narrowing the A1c gap: Personalized modeling of HbA1c– continuous glucose monitor discordance in type 1 diabetes

This study aims to characterize the temporal discordance between CGM-derived glucose exposure and HbA1c over time in individuals with type 1 diabetes, and to explore the development of a statistical model to adjust the relationship between these measures based on previously observed individual discrepancies. We paired CGM-data in a 60-day window prior to each HbA1c measurement and included individuals with type 1 diabetes with multiple pairs to assess and model discordance over time. Discordance was defined as difference between HbA1c and Glucose Management Indicator at each pair. At baseline (first pair), participants were categorized into three groups based on the degree of discordance: positive (≥0.5%), negative (≤-0.5%), and neutral (within ±0.5%). A multiple linear regression model incorporating historical discordance values, HbA1c levels, and the current GMI was utilized for an adjustment. 477 individuals were included and 1,523 instances of paired HbA1c and CGM-data were analyzed. Absolute discordance of ≥0.5% was observed in 31% of cases. In 51% of instances, the direction of discordance in each pair was maintained. In the modeling analysis, GMI accounted for 69% of the variance in HbA1c levels (r = 0.83, p < 0.001, MAE = 0.42%). Adjusting improved variance explainability to 82% (r = 0.90, p < 0.001, MAE = 0.33%). HbA1c-CGM discordance is highly prevalent, and while inter-individual discordance shows some degree of persistence, it also appears to vary over time for a substantial proportion of individuals. Adjusting for individual discordance in the short term can improve the alignment between adjusted GMI and laboratory-measured HbA1c.

Authors

Institutions

Publication Details

Journal
PLOS Digital Health
Published
2026-02-17
DOI
https://doi.org/10.1371/journal.pdig.0001229
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Narrowing the A1c gap: Personalized modeling of HbA1c– continuous glucose monitor discordance in type 1 diabetes

Camilla Heisel Nyholm Thomsen, Simon Lebech Cichosz, Irl B. Hirsch, Morten Hasselstrøm Jensen et al.
PLOS Digital Health
Diabetes Management and Research
article

Narrowing the A1c gap: Personalized modeling of HbA1c– continuous glucose monitor discordance in type 1 diabetes

Camilla Heisel Nyholm Thomsen, Simon Lebech Cichosz, Irl B. Hirsch, Morten Hasselstrøm Jensen, David C. Klonoff
article en

Abstract

This study aims to characterize the temporal discordance between CGM-derived glucose exposure and HbA1c over time in individuals with type 1 diabetes, and to explore the development of a statistical model to adjust the relationship between these measures based on previously observed individual discrepancies. We paired CGM-data in a 60-day window prior to each HbA1c measurement and included individuals with type 1 diabetes with multiple pairs to assess and model discordance over time. Discordance was defined as difference between HbA1c and Glucose Management Indicator at each pair. At baseline (first pair), participants were categorized into three groups based on the degree of discordance: positive (≥0.5%), negative (≤-0.5%), and neutral (within ±0.5%). A multiple linear regression model incorporating historical discordance values, HbA1c levels, and the current GMI was utilized for an adjustment. 477 individuals were included and 1,523 instances of paired HbA1c and CGM-data were analyzed. Absolute discordance of ≥0.5% was observed in 31% of cases. In 51% of instances, the direction of discordance in each pair was maintained. In the modeling analysis, GMI accounted for 69% of the variance in HbA1c levels (r = 0.83, p < 0.001, MAE = 0.42%). Adjusting improved variance explainability to 82% (r = 0.90, p < 0.001, MAE = 0.33%). HbA1c-CGM discordance is highly prevalent, and while inter-individual discordance shows some degree of persistence, it also appears to vary over time for a substantial proportion of individuals. Adjusting for individual discordance in the short term can improve the alignment between adjusted GMI and laboratory-measured HbA1c.

PLOS Digital HealthVol. 5(2)
Novo Nordisk (Denmark) (DK), University of Washington (US), Mills Peninsula Health Services (US), Aalborg University (DK)
Openalex Percentile: Top 55%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Narrowing the A1c gap: Personalized modeling of HbA1c– continuous glucose monitor discordance in type 1 diabetes — Camilla Heisel Nyholm Thomsen, Simon Lebech Cichosz, et al. · PLOS Digital Health (2026) | TGRS Research Map | TGRS