Evaluation of a Hybrid Surgical Approach for Transcatheter Mitral Valve Replacement in the Domestic Sheep Model

Background Novel cardiac valve prostheses require long-term studies assessing safety in animal models prior to clinical use. Although sheep are well-established preclinical models, the anatomy and morphology of the sheep heart impart unique challenges in the positioning and securement of transcatheter mitral valve replacement (TMVR) devices, resulting in early postoperative mortality. We developed a refined hybrid surgical approach to study the chronic in vivo performance of a novel TMVR device intended for regulatory approval. Methods Eleven adult sheep were enrolled in this study. Eight Abbott Next-Generation Cephea (Cephea) TMVR devices were implanted using a hybrid surgical approach, with the valve deployed and secured under direct visualization on cardiopulmonary bypass. For a control, three Medtronic Mosaic bioprostheses (Mosaic) were implanted with standard techniques. Sheep were survived for 20 weeks per regulatory guidance, followed by humane euthanasia and comprehensive necropsy. Results All sheep were successfully implanted and recovered from surgery, with 7/8 Cephea and 3/3 Mosaic animals surviving to the 20-week study endpoint. A surgical complication unrelated to TMVR performance resulted in one early death at 58 days post-operatively. At term, all Cephea valves performed comparably to controls, appearing well-healed within the annulus with competent, unobstructed leaflets. Conclusions Our novel hybrid surgical approach allowed for a comprehensive evaluation of the long-term performance of the Cephea, with 100% survival at 30 days and 88% at the 20-week endpoint. These results suggest that this approach may improve chronic survival in animal studies evaluating the safety of novel TMVR devices prior to clinical investigation.

Authors

Institutions

Publication Details

Journal
Journal of the Heart Valve Society
Published
2026-02-17
DOI
https://doi.org/10.1177/30494826261424812
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a Hybrid Surgical Approach for Transcatheter Mitral Valve Replacement in the Domestic Sheep Model

Walt Tollison, Mike Evans, K. N. Potel, M. T. Lahti et al.
Journal of the Heart Valve Society
Cardiac Valve Diseases and Treatments
article

Evaluation of a Hybrid Surgical Approach for Transcatheter Mitral Valve Replacement in the Domestic Sheep Model

Walt Tollison, Mike Evans, K. N. Potel, M. T. Lahti, L. Ogle, R. F. Kelly, Z. Vidlund, J. P. Carney, A. M. Kaparos, R. W. Bianco, J. T. Schappa Faustich, E. Liljequist
article en

Abstract

Background Novel cardiac valve prostheses require long-term studies assessing safety in animal models prior to clinical use. Although sheep are well-established preclinical models, the anatomy and morphology of the sheep heart impart unique challenges in the positioning and securement of transcatheter mitral valve replacement (TMVR) devices, resulting in early postoperative mortality. We developed a refined hybrid surgical approach to study the chronic in vivo performance of a novel TMVR device intended for regulatory approval. Methods Eleven adult sheep were enrolled in this study. Eight Abbott Next-Generation Cephea (Cephea) TMVR devices were implanted using a hybrid surgical approach, with the valve deployed and secured under direct visualization on cardiopulmonary bypass. For a control, three Medtronic Mosaic bioprostheses (Mosaic) were implanted with standard techniques. Sheep were survived for 20 weeks per regulatory guidance, followed by humane euthanasia and comprehensive necropsy. Results All sheep were successfully implanted and recovered from surgery, with 7/8 Cephea and 3/3 Mosaic animals surviving to the 20-week study endpoint. A surgical complication unrelated to TMVR performance resulted in one early death at 58 days post-operatively. At term, all Cephea valves performed comparably to controls, appearing well-healed within the annulus with competent, unobstructed leaflets. Conclusions Our novel hybrid surgical approach allowed for a comprehensive evaluation of the long-term performance of the Cephea, with 100% survival at 30 days and 88% at the 20-week endpoint. These results suggest that this approach may improve chronic survival in animal studies evaluating the safety of novel TMVR devices prior to clinical investigation.

Journal of the Heart Valve Society
University of Minnesota System (US), Abbott (United Kingdom) (GB)
Good health and well-being
Openalex Percentile: Top 56%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.